APPLICATION

Used as fixed installation cable for supplying machines and equipment.

Certificates
Technical Information

CONDUCTOR : Electrolytic, stranded, copper wire IEC 60228 Class 1 or 2
INSULATION : PVC
SEPERATOR : Semiconductor Jayer
SCREEN : Cores are individualJy screened with copper backed tape
LAYUP : All cores are Jaid up in contact with each other.
BEDDING : PVC based bedding compound.
ARMOUR : Two layers of galvanized steel pilable armour.
SEPERATOR : Galvanized steel tape (optional).
OUTER SHEATH : Speacial PVC compound.

RELATED STANDARDS : MGM 109/1983
RATED VOLTAGE : 3800/6600 V
TEST VOLTAGE : 10 kV

Cross Section 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185
Phase and Earth Conductors
Number and cross section mm2 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185
Cable details
Radial thickness of inner sheath mm 1.4 1.8 1.8 1.8 1.8 2.2 2.2 2.2 2.6
lnner sheath diameter mm 30.0 34.0 36.5 37.9 40.7 44.7 48.6 52.7 56.9
Size of armour mm 1/1,6 1/2,0 1/2,0 1/2,0 1/2,0 1/2,5 1/2,5 1/2,5 1/2,5
Radial thickness of outer sheath mm 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9
Min. overall diameter mm 40.5 45.6 48.5 51.0 54.5 61.5 65.0 69.0 74.0
Max. overall diameter mm 44.5 49.6 52.5 55.0 58.5 65.5 69.0 73.0 78.0
Min. bending radius mm 445 496 525 550 585 655 690 730 780
Appx. cable weight kg/km 4,850 6,250 6,950 7,850 9,050 11,850 13,200 14,850 17,050
Copper weight kg/km 631 900 1,208 1,650 2,316 3,086 3,976 5,070 6,368
Electrical details
“Continuous current rating at 25°c Ambient” A 94 125 150 175 220 265 305 345 390
Max. DC resistance at 20°C
Phase and earth conductors Ω/km 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991
Armour Ω/km 1.53 0.969 0.699 0.516 0.357 0.257 0.204 0.165 0.132

 