Languages :

Mgm Types

Home » Mining Cables » MGM-111-TYPE-620-TYPE-621

MGM-111-TYPE-620-TYPE-621

APPLICATION

Used far supplying excavating, crushing machines and equipment.

Certificates
Technical Information

CONDUCTOR : Electrolytic, stranded, tinned copper wire IEC 60228 Class 5
SEPERATOR : Semiconduct ing layer
INSULATION : EPR (Ground core is not insulated in TİP 620)
SEPERATOR : Semiconducting layer
SCREEN : Tinned copper / Nylon braided screen over insulated cores.
LAYUP : Al/ cores are laid up in contact with each other.
BEDD/NG : Rubber based bedding compound.
ARMOUR : Galvanized stee/ pliable armour.
SEPERATOR : Galvanized steel tape or water blocking tape (optional)
OUTER SHEATH : Heavy duty chloroprene outer sheath.

RELATED STANDARDS : MGM 111 / 1985
RATED VOLTAGE : 3800/6600 V
TEST VOLTAGE : 15 kV

MGM 111 TYPE 620
Cross section 3×16+16 3×25+16 3×35+16 3×50+25 3×70+35 3×95+50 3×120+70
Phase conductor
lnsulation thickness mm 5.0 5.0 5.0 5.0 5.0 5.0 5.0
Earth conductor
Number and cross section mm2 1×16 1×16 1×16 1×25 1×35 1×50 1×70
Stranding mm 126/0,40 126/0,40 126/0,40 196/0,40 276/0,40 396/0,40 360/0,50
lnsulation thickness mm
Cable details
Radial thickness of inner sheath mm 3.8 3.8 3.8 5.0 5.0 5.0 5.0
Size of armour mm 7/0,7 7/0,7 7/0,9 7/0,9 7/0,9 7/1,25 7/1,25
Radial thickness of outer sheath mm 5.6 6.0 6.3 6.7 7.2 7.8 8.1
Min. overall diameter mm 67.2 71.4 75.4 85.1 91.2 97.4 100.5
Max. overall diameter mm 70.4 74.6 78.6 88.6 94.6 100.9 105.2
Min. bending radius mm 634 672 708 798 852 909 947
Appx. cable weight kg/km 7,150 8,150 9,750 11,800 13,800 14,600 19,500
Copper weight kg/km 990 1,300 1,650 2,250 3,150 4,200 5,050
Electrical details
“Continuous current rating at 25°C Ambient” A 85 110 135 170 205 250 295
Max. DC resistance at 20’C
Phase Conductor ntkm 1.24 0.795 0.565 0.393 0.277 0.21 0.164
3 screens and earth in parallel connection ntkm 0.70 0.60 0.50 0.50 0.34 0.28 0.18
Armour ntkm 0.79 0.74 0.70 0.46 0.43 0.40 0.38
MGM 111 TYPE 621
Cross section 4×16 4×25 4×35 4×50 4×70 4×95 4×120 4×150
Phase conductor
Number and cross section mm2 4×16 4×25 4×35 4×50 4×70 4×95 4×120 4×150
Stranding mm 126/0,40 196/0,40 276/0,40 396/0,40 360/0,50 475/0,50 608/0,50 756/0,50
lnsulation thickness mm 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0
Cable details
Radial thickness of inner sheath mm 3.8 3.8 3.8 5.0 5.0 5.0 5.0 5.0
Size of armour mm 7/0,7 7/0,7 7/0,9 7/0,9 7/0,9 7/1,25 7/1,25 7/1,25
Radial thickness of outer sheath mm 5.6 6.0 6.3 6.7 7.2 7.8 8.1 5.6
Min. overall diameter mm 67.2 71.4 75.4 85.1 91.2 97.4 100.5 107.5
Max. overall diameter mm 70.4 74.6 78.6 88.6 94.6 100.9 105.2 111.0
Min. bending radius mm 634 672 708 798 852 909 947 999
Appx. cable weight kg/km 7,350 8,500 10,000 12,900 14,300 15,200 19,500 21,500
Copper weight kg/km 1,150 1,550 2,100 2,750 3,800 5,000 5,950 7,000
Electrical details
“Continuous current rating at 25°C Ambient” A 85 110 135 170 205 250 295 345
Max. DC resistance at 20’C
Conductors ntkm 1.24 0.795 0.565 0.393 0.277 0.21 0.164 0.124
Armour ntkm 0.79 0.74 0.70 0.46 0.43 0.40 0.38 0.35

 

We use cookies on our website to provide you a better experience. For detailed information please visit Our Cookie Policy and Clarification Text.