Languages :

Mgm Types

Home » Mining Cables » MGM 115 TYPE 11

MGM 115 TYPE 11

APPLICATION

Used for supplying excavating, crushing machines and equipment.

Certificates
Technical Information

CONDUCTOR : Electrolytic, stranded, tinned copper wire IEC 60228 Class 5
INSULATION : EPR
SEPERATOR : Colored Textile tape for core identification.
SCREEN : Tinned copper / Nylon braided screen over phase cores.
LAYUP : All cores are laid up in contact with each other.
BEDDING : Rubber based bedding compound.
OUTER SHEATH : Heavy duty chloroprene outer sheath.

RELATED STANDARDS : MGM 115/1985
RATED VOLTAGE : 660/1100 V
TEST VOLTAGE : 2,5 kV

Cross Section3×16+16
Phase Conductor
Number and cross sectionmm23×16
Insulation thicknessmm1.5
Pilot Conductor
Number and cross sectionmm21×16
Strandingmm126/0,40
Conductor diameterNom. mm5.50
Insulation thicknessmm1.5
Cable details
Radial diameter of outer sheathmm3.1
Min. overall diametermm30.9
Max. overall diametermm34.0
Min. bending radiusmm306
Max. pulling tensionkgf384
Appx. cable weightkg/km2
Copper weightkg/km1.1
Electrical details
“Continuous current
rating at 25°C Ambient”
A85
“Intermittent current
rating at 25°C Ambient”
A96
Max. DC resistance at 20°C
Phase ConductorΩ /km1.24
Pilot ConductorΩ /km1.24
4 screens in parallel connectionΩ /km1.05
Nom. reactance at 50HzΩ /km0.109
Nom. reactance at 60HzΩ /km0.131
Min. insulation
resistance at 20°C
M Ω /km435
3 phase voltage drop
on full load current
mV/A/m2.62

 

We use cookies on our website to provide you a better experience. For detailed information please visit Our Cookie Policy and Clarification Text.