APPLICATION
Used for supplying excavating, crushing machines and equipment, as well as coalface lighting.
CONDUCTOR : Electrolytic, stranded, tinned copper wire IEC 60228 Class 5
INSULATION : EPR
LAYUP : All cores are laid up in contact with each other.
BEDDING : Rubber based bedding compound.
ARMOUR : Galvanized steel pliable armour.
OUTER SHEATH : Heavy duty chloroprene outer sheath.
RELATED STANDARDS : BS 6708
RATED VOLTAGE : 320/550 V
TEST VOLTAGE : 1.5 kV
| Cross Section | 4×4 | 5×4 | |
|---|---|---|---|
| Conductors | |||
| Number and cross section | mm2 | 4×4 | 5×4 |
| Insulation thickness | mm | 1.0 | 1.0 |
| Cable details | |||
| Radial thickness of inner sheath | mm | 2.0 | 2.0 |
| Min. inner sheath diameter | mm | 15.8 | 17.2 |
| Max. inner sheath diameter | mm | 17.8 | 19.2 |
| Size of armour | mm | 7/0,45 | 7/0,45 |
| Outer sheath thickness | mm | 2.5 | 2.5 |
| Min. overall diameter | mm | 23.5 | 24.9 |
| Max. overall diameter | mm | 26.0 | 27.4 |
| Min. bending radius | mm | 234 | 247 |
| Max. pulling tension | kgf | 96 | 100 |
| Appx. cable weight | kg/km | 1.1 | 1.23 |
| Copper weight | kg/km | 154 | 192 |
| Electrical details | |||
| “Continuous current rating at 25°C Ambient” | A | 28 | 28 |
| Max. DC resistance at 20°C | |||
| Phase Conductor | Ω /km | 5.09 | 5.09 |
| Armour | Ω /km | 5.07 | 4.63 |