APPLICATION
Used for supplying hand-held drilling machines
CONDUCTOR : Electrolytic, stranded, tinned copper wire IEC 60228 Class 5
INSULATION : EPR
LAYUP : All cores are laid up without contacting each other.
BEDDING : Conducting elastromeric compound.
OUTER SHEATH : Heavy duty chloroprene outer sheath.
RELATED STANDARDS : BS 6708
RATED VOLTAGE : 125/72 V
TEST VOLTAGE : 1,5 kV
| Cross Section | 5×6 | |
|---|---|---|
| Conductors | ||
| Number and cross section | mm2 | 5×6 |
| Insulation thickness | mm | 1.0 |
| Cable details | ||
| Radial thickness of conducting elastomeric inner sheath | mm | 1.5 |
| Outer sheath thickness | mm | 2.5 |
| Min. overall diameter | mm | 24.8 |
| Max. overall diameter | mm | 26.8 |
| Min. bending radius | mm | 268 |
| Appx. cable weight | kg/km | 1.02 |
| Copper weight | kg/km | 150 |
| Electrical details | ||
| “Continuous current rating at 25°C Ambient” | A | 46 |
| Max. DC resistance at 20°C | ||
| Conductors | Ω /km | 3.48 |