Languages :

BS Types

Home » Mining Cables » BS 6708 TYPE 506, 512, 518, 524

BS 6708 TYPE 506, 512, 518, 524

APPLICATION

Used as control cable in large mining machines and connecting surrounding machine segments.

Certificates
Technical Information

CONDUCTOR : Electrolytic, stranded, tinned copper wire IEC 60228 Class 5
INSULATION : EPR or TPE
SCREEN : Tinned copper / Nylon braided screen over cores.
LAYUP : All cores are laid up in contact with each other.
BEDDING : Rubber based bedding compound.
ARMOUR : Galvanized steel pliable armour.
OUTER SHEATH : Heavy duty chloroprene outer sheath

RELATED STANDARDS : BS 6708
RATED VOLTAGE : 320/550 V
TEST VOLTAGE : 1,5 kV

Cross Section6×1,3412×1,3418×1,3424×0,93
Conductors
Number and cross sectionmm26×1,3412×1,3418×1,3424×0,93
Insulation thicknessmm0.40.40.40.4
Cable details
Radial thickness of inner sheathmm3.51.81.51.5
Min. inner sheath diametermm14.814.816.517.9
Max. inner sheath diametermm16.816.818.519.9
Size of armourmm7/0,457/0,457/0,457/0,45
Outer sheath thicknessmm1.81.81.81.8
Min. overall diametermm22.122.122.824.2
Max. overall diametermm23.623.625.326.7
Min. bending radiusmm236236253267
Appx. cable weightkg/km1.021.21.41.6
Copper weightkg/km150300450450
Electrical details
“Continuous current
rating at 25°C Ambient”
A1613118
Max. DC resistance at 20°C
ConductorsΩ /km15.415.415.422.1
ArmourΩ /km5.405.404.764.50
3 Ekran Paralel BağlıΩ /km37.337.337.344.7
DC or single phase voltage dropmV/A/m34343450
3 phase voltage dropmV/A/m30303043

 

We use cookies on our website to provide you a better experience. For detailed information please visit Our Cookie Policy and Clarification Text.