Languages :

Mgm Types

Home » Mining Cables » MGM 109 TYPE 1012,1013,1014

MGM 109 TYPE 1012,1013,1014

APPLICATION

Used as fixed installation cable for supplying machines and equipment.

Certificates
Technical Information

CONDUCTOR : Electrolytic, stranded, copper wire IEC 60228 Class 1 or 2
INSULATION : PVC
LAYUP : All cores are laid up in contact with each other.
BEDDING : PVC based bedding compound.
ARMOUR : Galvanized steel pliable armour.
SEPERATOR : Galvanized steel tape (optional).
OUTER SHEATH : Speacial PVC compound.

RELATED STANDARDS : MGM 109/1983
RATED VOLTAGE : 600/1000 V
TEST VOLTAGE : 3 kV

Cross Section2×1,52×2,52×42×62×102×16
MGM 109 TYPE 101
Conductors
Cable details
Radial thickness of inner sheathmm0.80.80.80.80.80.8
Inner sheath diametermm7.08.210.211.314.015.8
Size of armourmm1/0,91/0,91/0,91/0,91/1,251/1,25
Radial thickness of outer sheathmm1.31.41.41.51.61.6
Min. overall diametermm9.711.113.114.518.119.9
Max. overall diametermm13.715.117.118.522.123.9
Min. bending radiusmm124136154167199216
Appx. cable weightkg/km3203954806209501.28
Copper weightkg/km305080120220380
Electrical details
“Continuous current
rating at 25°C Ambient”
A182634446182
Max. DC resistance at 20°C
ConductorsΩ /km12.17.414.613.081.831.15
ArmourΩ /km20.1712.307.685.133.051.92
Cross Section3×1,53×2,53×43×63×103×163×253×353×503×703×95
MGM 109 TYPE 101
Phase and Earth Conductors
Number and cross sectionmm23×1,53×2,53×43×63×103×163×253×353×503×703×95
Insulation thicknessmm0.80.80.80.81.01.01.21.21.41.41.6
Cable details
Radial thickness of inner sheathmm0.80.80.80.80.80.81.01.01.01.21.2
Inner sheath diametermm7.48.810.912.015.016.620.322.526.230.034.8
Size of armourmm1/0,91/0,91/0,91/1,251/1,251/1,251/1,601/1,601/1,801/2,01/2,0
Radial thickness of outer sheathmm1.41.41.41.51.61.61.71.81.92.02.1
Min. overall diametermm9.711.113.114.518.120.725.327.932.236.441.6
Max. overall diametermm13.715.117.118.522.124.729.331.936.240.445.6
Min. bending radiusmm124136154167199223264288326364411
Appx. cable weightkg/km3504205607801.121.42.152.453.44.425.8
Copper weightkg/km45751201903105308101.161.722.343.2
Electrical details
“Continuous current
rating at 25°C Ambient”
A182634446182108135168207250
Max. DC resistance at 20°C
Phase and earth conductorsΩ /km12.17.414.613.081.831.150.7270.5240.3870.2680.193
ArmourΩ /km20.1712.307.685.133.051.921.210.8730.6450.4470.322
Cross Section4×1,54×2,54×44×64×104×164×254×354×504×704×95
MGM 109 TYPE 1014
Phase and Earth Conductors
Number and cross sectionmm24×1,54×2,54×44×64×104×164×254×354×504×704×95
Insulation thicknessmm0.80.80.80.81.01.01.21.21.41.41.6
Cable details
Radial thickness of inner sheathmm0.80.80.80.80.81.01.01.01.21.21.2
Inner sheath diametermm8.19.511.913.216.518.722.625.029.633.438.7
Size of armourmm1/0,91/0,91/1,251/1,251/1,251/1,601/1,601/1,601/2,01/2,01/2,0
Radial thickness of outer sheathmm1.41.41.51.51.61.71.81.92.02.12.2
Min. overall diametermm11.012.515.817.220.823.928.030.636.240.245.7
Max. overall diametermm15.016.519.821.224.827.932.034.640.244.249.7
Min. bending radiusmm135149179191224252288312362398448
Appx. cable weightkg/km4205007508201.351.92.613.14.35.47
Copper weightkg/km601001602404006601.051.462.093.014.1
Electrical details
“Continuous current
rating at 25°C Ambient”
A182634446182108135168207250
Max. DC resistance at 20°C
Phase and earth conductorsΩ /km12.17.414.613.081.831.150.7270.5240.3870.2680.193
ArmourΩ /km20.1712.307.685.133.051.921.210.8730.6450.4470.322

 

We use cookies on our website to provide you a better experience. For detailed information please visit Our Cookie Policy and Clarification Text.