Languages :

Mgm Types

Home » Mining Cables » MGM 115 TYPE 11

MGM 115 TYPE 11

APPLICATION

Used for supplying excavating, crushing machines and equipment.

Certificates
Technical Information

CONDUCTOR : Electrolytic, stranded, tinned copper wire IEC 60228 Class 5
INSULATION : EPR
SEPERATOR : Colored Textile tape for core identification.
SCREEN : Tinned copper / Nylon braided screen over phase cores.
LAYUP : All cores are laid up in contact with each other.
BEDDING : Rubber based bedding compound.
OUTER SHEATH : Heavy duty chloroprene outer sheath.

RELATED STANDARDS : MGM 115/1985
RATED VOLTAGE : 660/1100 V
TEST VOLTAGE : 2,5 kV

Cross Section 3×16+16
Phase Conductor
Number and cross section mm2 3×16
Insulation thickness mm 1.5
Pilot Conductor
Number and cross section mm2 1×16
Stranding mm 126/0,40
Conductor diameter Nom. mm 5.50
Insulation thickness mm 1.5
Cable details
Radial diameter of outer sheath mm 3.1
Min. overall diameter mm 30.9
Max. overall diameter mm 34.0
Min. bending radius mm 306
Max. pulling tension kgf 384
Appx. cable weight kg/km 2
Copper weight kg/km 1.1
Electrical details
“Continuous current
rating at 25°C Ambient”
A 85
“Intermittent current
rating at 25°C Ambient”
A 96
Max. DC resistance at 20°C
Phase Conductor Ω /km 1.24
Pilot Conductor Ω /km 1.24
4 screens in parallel connection Ω /km 1.05
Nom. reactance at 50Hz Ω /km 0.109
Nom. reactance at 60Hz Ω /km 0.131
Min. insulation
resistance at 20°C
M Ω /km 435
3 phase voltage drop
on full load current
mV/A/m 2.62

 

We use cookies on our website to provide you a better experience. For detailed information please visit Our Cookie Policy and Clarification Text.