Languages :

Instrumentation Cables

Home » Instrumentation Cables » RE-Y(St)Y-fl TIMF

RE-Y(St)Y-fl TIMF

Application
These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications. These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.

Available Features on Request

• 300 V version

• Yw 105ºC version

• Hydrocarbon resistant

• Yv type reinforced sheath

• Oil resistant

• Anti termit / anti rodent

• UV resistant

• LSF (Low Smoke) version

Certificates
Technical Information

CONDUCTOR :Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)
INSULATION :PVC compound to EN50290-2-21 Black / White / Red twisted triads with numbered cores
BINDER TAPE :Polyester foil on each twisted triad
INDIVIDUAL SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
BINDER TAPE :Polyester foil on overall cable core formed by stranded triples
COLLECTIVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
OUTER SHEATH :Flame retardant PVC compound to EN50290-2-22 Blue for intrinsically safe cable Black for UV resistant and/or non-instrinsically safe cable Other colours on request

RATED VOLTAGE :500 V a.c.
AC TEST VOLTAGE :2000 V x 1 min. (core:core / core: screen)
WORKING TEMPERATURE : -30°C / + 70°C (during operation) – 5 °C / + 50°C (during installation)
MIN BENDING RADIUS (FIXED) :7,5 x D
CONSTRUCTION :EN 50288-7
MATERIAL TYPES & TESTS :EN 50290-2 series
ELECTRICAL & MECHANICAL TESTS :EN 50289 series
FLAME RETARDANT :IEC 60332 / 1-2, IEC 60332 / 3-24 Cat C

Conductor size (Class 2) nom. mm2 0.5 0.75 1 1.3 1.5 2.5
Conductor resistance max. Ω/km 36.7 25 18.5 14.2 12.3 7.6
Insulation resistance min. MΩxkm 100
L/R ratio max. µH/Ω 25 25 25 40 40 60
(*) At 20 °C
Cross Sections (mm2) Nominal Overall Diameter (mm) Approximate Weight (kg/km)
2x3x0,5 11 123
4x3x0,5 13 201
8x3x0,5 17.5 360
10x3x0,5 20.1 447
12x3x0,5 20.9 523
16x3x0,5 23.4 675
20x3x0,5 26.3 832
24x3x0,5 29.3 994
2x3x0,75 12.1 150
4x3x0,75 14.4 251
5x3x0,75 15.9 307
6x3x0,75 17.3 358
8x3x0,75 19.7 464
10x3x0,75 22.5 575
12x3x0,75 23.5 674
16x3x0,75 26.3 871
20x3x0,75 29.5 1075
24x3x0,75 32.9 1284
2x3x1 12.7 172
4x3x1 14.8 280
5x3x1 16.4 344
6x3x1 18.1 410
8x3x1 20.3 521
10x3x1 23.5 659
12x3x1 24.3 761
16x3x1 27.2 986
20x3x1 30.5 1217
24x3x1 34.2 1471
2x3x1,3 13.5 200
4x3x1,3 15.9 338
5x3x1,3 17.4 407
6x3x1,3 19.2 486
8x3x1,3 21.8 631
10x3x1,3 25 784
12x3x1,3 26 921
16x3x1,3 29.1 1195
20x3x1,3 32.7 1477
24x3x1,3 36.5 1764
2x3x1,5 14 214
4x3x1,5 16.6 366
5x3x1,5 18.4 450
6x3x1,5 20.1 526
8x3x1,5 22.8 684
10x3x1,5 26.3 962
12x3x1,5 27.2 1000
16x3x1,5 30.5 1300
20x3x1,5 34.4 1621
24x3x1,5 38.4 1936
2x3x2,5 16.7 304
4x3x2,5 19.8 528
5x3x2,5 21.9 650
6x3x2,5 24.1 775
8x3x2,5 27.4 1010
10x3x2,5 31.6 1267
12x3x2,5 32.7 1473
16x3x2,5 36.8 1935
20x3x2,5 41.3 2391
24x3x2,5 46.3 2877
We use cookies on our website to provide you a better experience. For detailed information please visit Our Cookie Policy and Clarification Text.