Languages :

Instrumentation Cables

Home » Instrumentation Cables » RE-2Y(St)HSWAH PIMF

RE-2Y(St)HSWAH PIMF

Application
These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.

Available Features on Request

• 300 V version

• Hv type reinforced sheath

• Hydrocarbon resistant

• Anti termit / anti rodent

• Oil resistant

• UV resistant

Certificates
Technical Information

CONDUCTOR :Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)
INSULATION :PE-Polyethylene compound to EN50290-2-23 Black / White twisted pairs with numbered cores
BINDER TAPE :Polyester foil on each twisted pair
INDIVIDUAL SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
BINDER TAPE :Polyester foil on overall cable core formed by stranded pairs
COLLECTIVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
INNER SHEATH :LSZH compound to EN50290-2-27
ARMOUR :Round galvanised steel wires to EN 10257-1
OUTER SHEATH :Halogen free flame retardant LSZH compound to EN50290-2-27 Blue for intrinsically safe cable Black for UV resistant and/or non-instrinsically safe cable Gray for indoor applications Other colours on request

RATED VOLTAGE :500 V a.c.
AC TEST VOLTAGE :2000 V x 1 min. (core:core / core: screen)
WORKING TEMPERATURE :-30°C / + 70°C (during operation) – 5 °C / + 50°C (during installation)
MIN BENDING RADIUS (FIXED) :10 x D
CONSTRUCTION :EN 50288-7
MATERIAL TYPES & TESTS :EN 50290-2 series
ELECTRICAL & MECHANICAL TESTS :EN 50289 series
FLAME RETARDANT :IEC 60332 / 1-2, IEC 60332 / 3-24 Cat C
HALOGEN CONTENT :IEC 60754 / 1-2
SMOKE EMISSION :IEC 61034 / 1-2

Conductor size (Class 2) nom. mm2 0.5 0.75 1 1.3 1.5 2.5
Conductor resistance max. Ω/km 36.7 25 18.5 14.2 12.3 7.6
Insulation resistance min. MΩxkm 5000
L/R ratio max. µH/Ω 25 25 25 40 40 60
(*) At 20 °C
Cross Sections (mm2) Nominal Overall Diameter (mm) Approximate Weight (kg/km)
2x2x0,5 14.7 361
4x2x0,5 16.3 447
8x2x0,5 21.3 775
10x2x0,5 23.3 890
12x2x0,5 23.9 950
16x2x0,5 26.2 1118
20x2x0,5 28.6 1281
24x2x0,5 32 1660
2x2x0,75 15.8 408
4x2x0,75 17.8 521
5x2x0,75 19 578
6x2x0,75 21 761
8x2x0,75 23.2 890
10x2x0,75 25.7 1043
12x2x0,75 26.4 1115
16x2x0,75 29 1325
20x2x0,75 32.6 1723
24x2x0,75 35.9 1998
2x2x1 16.2 425
4x2x1 18.3 550
5x2x1 19.5 616
6x2x1 21.8 815
8x2x1 23.8 951
10x2x1 26.5 1108
12x2x1 27.2 1197
16x2x1 29.8 1415
20x2x1 33.6 1856
24x2x1 37.2 2170
2x2x1,3 16.9 460
4x2x1,3 19.1 604
5x2x1,3 21.4 805
6x2x1,3 22.9 902
8x2x1,3 25.3 1068
10x2x1,3 28 1240
12x2x1,3 28.9 1347
16x2x1,3 32.3 1785
20x2x1,3 35.9 2123
24x2x1,3 39.4 2441
2x2x1,5 17.5 490
4x2x1,5 19.6 630
5x2x1,5 21.9 850
6x2x1,5 23.4 940
8x2x1,5 25.9 1114
10x2x1,5 28.9 1308
12x2x1,5 29.7 1421
16x2x1,5 33.3 1885
20x2x1,5 37.1 2260
24x2x1,5 40.7 2595
2x2x2,5 19.7 594
4x2x2,5 23.2 926
5x2x2,5 25.1 1062
6x2x2,5 26.9 1188
8x2x2,5 29.9 1432
10x2x2,5 34.6 1935
12x2x2,5 35.6 2105
16x2x2,5 39.1 2502
20x2x2,5 44.2 3270
24x2x2,5 48.9 3804
We use cookies on our website to provide you a better experience. For detailed information please visit Our Cookie Policy and Clarification Text.