Languages :

Instrumentation Cables

Home » Instrumentation Cables » RE-2X(St)HSWAH-TIMF..CI

RE-2X(St)HSWAH-TIMF..CI

Application
These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply. Recommended for use where circuit integrity is required in case of fire.

Available Features on Request

• 300 V version

• Hv type reinforced sheath

• Hydrocarbon resistant

• Anti termit / anti rodent

• Oil resistant

• UV resistant

Certificates
Technical Information

CONDUCTOR :Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)
INSULATION :Mica tape + XLPE compound to EN50290-2-29 Black / White / Red twisted triads with numbered cores
BINDER TAPE :Polyester foil on each twisted triad
INDIVIDUAL SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
BINDER TAPE :Polyester foil on overall cable core formed by stranded pairs
COLLECTIVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
INNER SHEATH :LSZH compound to EN50290-2-27
ARMOUR :Round galvanised steel wires to EN 10257-1
OUTER SHEATH :Halogen free flame retardant LSZH compound to EN50290-2-27 Orange or Red for circuit integrity Blue for intrinsically safe cable Black for UV resistant and/or non-instrinsically safe cable

RATED VOLTAGE :500 V a.c.
AC TEST VOLTAGE :2000 V x 1 min. (core:core / core: screen)
WORKING TEMPERATURE :-40°C / + 90°C (during operation) – 5 °C / + 50°C (during installation)
MIN BENDING RADİUS (FIXED) :10 x D
CONSTRUCTION :EN 50288-7
MATERIAL TYPES & TESTS :EN 50290-2 series
ELECTRICAL & MECHANICAL TESTS :EN 50289 series
FLAME RETARDANT :IEC 60332 / 1-2, IEC 60332 / 3-24 Cat C
FIRE RESISTANCE :IEC 60331 / 21, IEC 60331 / 1-2
HALOGEN CONTENT :IEC 60754 / 1-2
SMOKE EMISSION :IEC 61034 / 1-2

Conductor size (Class 2),nom.,mm2,0.5,0.75,1,1.3,1.5,2.5
Conductor resistance,max.,Ω/km,36.7,25,18.5,14.2,12.3,7.6
Insulation resistance,min.,MΩxkm,5000,,,,,
L/R ratio,max.,µH/Ω,25,25,25,40,40,60
(*) At 20 °C
Cross Sections (mm2) Nominal Overall Diameter (mm) Approximate Weight (kg/km)
2x3x0,5 17.7 475
4x3x0,5 19.9 604
8x3x0,5 26.3 1061
10x3x0,5 29.3 1240
12x3x0,5 30.2 1336
16x3x0,5 33.8 1774
20x3x0,5 37.7 2117
24x3x0,5 41.4 2421
2x3x0,75 18.6 518
4x3x0,75 21.9 805
5x3x0,75 23.5 897
6x3x0,75 25.4 1012
8x3x0,75 27.9 1187
10x3x0,75 31.2 1396
12x3x0,75 33 1712
16x3x0,75 36.7 2067
20x3x0,75 40.4 2403
24x3x0,75 45.2 3062
2x3x1 19 540
4x3x1 22.4 848
5x3x1 24 947
6x3x1 25.9 1068
8x3x1 28.6 1260
10x3x1 32.9 1695
12x3x1 33.8 1820
16x3x1 37.5 2218
20x3x1 41.4 2584
24x3x1 46.7 3330
2x3x1,3 19.8 588
4x3x1,3 23.3 921
5x3x1,3 25.2 1053
6x3x1,3 27.1 1177
8x3x1,3 30.1 1404
10x3x1,3 34.8 1900
12x3x1,3 35.8 2062
16x3x1,3 39.3 2460
20x3x1,3 44.4 3200
24x3x1,3 49.2 3720
2x3x1,5 20.8 717
4x3x1,5 23.7 958
5x3x1,5 25.7 1097
6x3x1,5 27.6 1226
8x3x1,5 30.7 1476
10x3x1,5 35.5 1980
12x3x1,5 36.7 2172
16x3x1,5 40.4 2598
20x3x1,5 45.4 3350
24x3x1,5 50.3 3920
2x3x2,5 23.9 900
4x3x2,5 27.3 1215
5x3x2,5 29.7 1404
6x3x2,5 33 1795
8x3x2,5 37.1 2200
10x3x2,5 41.6 2594
12x3x2,5 43.6 3132
16x3x2,5 48.6 3850
20x3x2,5 53.7 4523
24x3x2,5 60.8 5805
We use cookies on our website to provide you a better experience. For detailed information please visit Our Cookie Policy and Clarification Text.