Languages :

Instrumentation Cables

Home » Instrumentation Cables » RE-2Y(St)H PIMF

RE-2Y(St)H PIMF

Application
These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.

Available Features on Request

• 300 V version

• Hv type reinforced sheath

• Hydrocarbon resistant

• Anti termit / anti rodent

• Oil resistant

• UV resistant

Certificates
Technical Information

CONDUCTOR :Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)
INSULATION :PE-Polyethylene compound to EN50290-2-23 Black / White twisted pairs with numbered cores
BINDER TAPE :Polyester foil on each twisted pair
INDIVIDUAL SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
BINDER TAPE :Polyester foil on overall cable core formed by stranded pairs
COLLECTIVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
OUTER SHEATH :Halogen free flame retardant LSZH compound to EN50290-2-27 Blue for intrinsically safe cable Black for UV resistant and/or non-instrinsically safe cable Gray for indoor applications Other colours on request

RATED VOLTAGE :500 V a.c.
AC TEST VOLTAGE :2000 V x 1 min. (core:core / core: screen)
WORKING TEMPERATURE :-30°C / + 70°C (during operation) – 5 °C / + 50°C (during installation)
MIN BENDING RADIUS (FIXED) :7,5 x D
CONSTRUCTION :EN 50288-7
MATERIAL TYPES & TESTS :EN 50290-2 series
ELECTRICAL & MECHANICAL TESTS :EN 50289 series
FLAME RETARDANT :IEC 60332 / 1-2, IEC 60332 / 3-24 Cat C
HALOGEN CONTENT :IEC 60754 / 1-2
SMOKE EMISSION :IEC 61034 / 1-2

Conductor size (Class 2) nom. mm2 0.5 0.75 1 1.3 1.5 2.5
Conductor resistance max. Ω/km 36.7 25 18.5 14.2 12.3 7.6
Insulation resistance min. MΩxkm 5000
L/R ratio max. µH/Ω 25 25 25 40 40 60
(*) At 20 °C
Cross Sections (mm2) Nominal Overall Diameter (mm) Approximate Weight (kg/km)
2x2x0,5 10.1 96
4x2x0,5 11.7 145
8x2x0,5 16 263
10x2x0,5 18.2 325
12x2x0,5 18.8 370
16x2x0,5 21.1 474
20x2x0,5 23.7 583
24x2x0,5 26.4 696
2x2x0,75 11.2 115
4x2x0,75 13.2 184
5x2x0,75 14.4 217
6x2x0,75 16 260
8x2x0,75 18.1 322
10x2x0,75 20.6 410
12x2x0,75 21.3 468
16x2x0,75 24 528
20x2x0,75 26.8 741
24x2x0,75 30 884
2x2x1 11.6 126
4x2x1 13.7 204
5x2x1 15 242
6x2x1 16.5 290
8x2x1 18.7 372
10x2x1 21.4 488
12x2x1 22.1 526
16x2x1 24.7 678
20x2x1 27.8 836
24x2x1 31 998
2x2x1,3 12.5 150
4x2x1,3 14.5 237
5x2x1,3 16.1 291
6x2x1,3 17.6 340
8x2x1,3 20 438
10x2x1,3 23 543
12x2x1,3 23.8 635
16x2x1,3 26.7 820
20x2x1,3 30 1010
24x2x1,3 33.4 1205
2x2x1,5 13 160
4x2x1,5 15.2 262
5x2x1,5 16.6 312
6x2x1,5 18.3 372
8x2x1,5 20.8 481
10x2x1,5 23.8 595
12x2x1,5 24.6 684
16x2x1,5 27.5 883
20x2x1,5 30.9 1090
24x2x1,5 34.7 1317
2x2x2,5 15.3 221
4x2x2,5 18.1 370
5x2x2,5 19.8 443
6x2x2,5 21.8 528
8x2x2,5 24.8 684
10x2x2,5 28.4 848
12x2x2,5 29.6 993
16x2x2,5 33.1 1284
20x2x2,5 37.4 1602
24x2x2,5 41.7 1910
We use cookies on our website to provide you a better experience. For detailed information please visit Our Cookie Policy and Clarification Text.