Languages :

Instrumentation Cables

Home » Instrumentation Cables » RE-Y(St)YSWAY-fl PIMF

RE-Y(St)YSWAY-fl PIMF

Application
These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.

Available Features on Request

• 300 V version

• Yw 105ºC version

• Hydrocarbon resistant

• Yv type reinforced sheath

• Oil resistant

• Anti termit / anti rodent

• UV resistant

• LSF (Low Smoke) version

Certificates
Technical Information

CONDUCTOR :Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)
INSULAION :PVC compound to EN50290-2-21 Black / White twisted pairs with numbered cores
BINDER TAPE :Polyester foil on each twisted pair
INDIVIDUAL SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
BINDER TAPE :Polyester foil on overall cable core formed by stranded pairs
COLLECTIVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
INNER SHEATH :PVC compound to EN50290-2-22
ARMOUR :Round galvanised steel wires to EN 10257-1
OUTER SHEATH :Flame retardant PVC compound to EN50290-2-22 Blue for intrinsically safe cable Black for UV resistant and/or non-instrinsically safe cable Other colours on request

RATED VOLTAGE :500 V a.c.
AC TEST VOLTAGE :2000 V x 1 min. (core:core / core: screen)
WORKING TEMPERATURE : -30°C / + 70°C (during operation) – 5 °C / + 50°C (during installation)
MIN BENDING RADIUS (FIXED) :10 x D
CONSTRUCTION :EN 50288-7
MATERIAL TYPES & TESTS :EN 50290-2 series
ELECTRICAL & MECHANICAL TESTS :EN 50289 series
FLAME RETARDANT :IEC 60332 / 1-2, IEC 60332 / 3-24 Cat C

Conductor size (Class 2) nom. mm2 0.5 0.75 1 1.3 1.5 2.5
Conductor resistance max. Ω/km 36.7 25 18.5 14.2 12.3 7.6
Insulation resistance min. MΩxkm 100
L/R ratio max. µH/Ω 25 25 25 40 40 60
(*) At 20 °C
Cross Sections (mm2) Nominal Overall Diameter (mm) Approximate Weight (kg/km)
2x2x0,5 14.7 367
4x2x0,5 16.3 458
8x2x0,5 21.3 798
10x2x0,5 23.3 920
12x2x0,5 23.9 982
16x2x0,5 26.2 1163
20x2x0,5 28.6 1336
24x2x0,5 32 1725
2x2x0,75 15.8 415
4x2x0,75 17.8 536
5x2x0,75 19 596
6x2x0,75 21 782
8x2x0,75 23.2 918
10x2x0,75 25.7 1080
12x2x0,75 26.4 1158
16x2x0,75 29 1382
20x2x0,75 32.6 1795
24x2x0,75 35.9 2084
2x2x1 16.2 434
4x2x1 18.3 565
5x2x1 19.5 635
6x2x1 21.8 837
8x2x1 23.8 980
10x2x1 26.5 1145
12x2x1 27.2 1243
16x2x1 29.8 1476
20x2x1 33.6 1930
24x2x1 37.2 2260
2x2x1,3 16.9 468
4x2x1,3 19.1 620
5x2x1,3 21.4 826
6x2x1,3 22.9 927
8x2x1,3 25.3 1100
10x2x1,3 28 1282
12x2x1,3 28.9 1396
16x2x1,3 32.3 1853
20x2x1,3 35.9 2208
24x2x1,3 39.4 2543
2x2x1,5 17.5 500
4x2x1,5 19.6 648
5x2x1,5 21.9 870
6x2x1,5 23.4 967
8x2x1,5 25.9 1150
10x2x1,5 28.9 1353
12x2x1,5 29.7 1475
16x2x1,5 33.3 1957
20x2x1,5 37.1 2350
24x2x1,5 40.7 3170
2x2x2,5 19.7 610
4x2x2,5 23.2 953
5x2x2,5 25.1 1095
6x2x2,5 26.9 1228
8x2x2,5 29.9 1486
10x2x2,5 34.6 2000
12x2x2,5 35.6 2185
16x2x2,5 39.1 2608
20x2x2,5 44.2 3404
24x2x2,5 48.9 3964
We use cookies on our website to provide you a better experience. For detailed information please visit Our Cookie Policy and Clarification Text.