Languages :

Defense Industry Cables

Home » Defense Industry Cables » VG 95218 Part 62 (FMGSGO)

VG 95218 Part 62 (FMGSGO)

Application

Used as fixed installation cable in telecommunication, signal, radio, radar and information systems in most areas, below and above deck on Navy vessels. They are not designed for continuous installation in water. Comply the general requirements of BV 3400 (Specification for Cable Systems of German Navy Vessels

Certificates
Technical Information

Conductor: Electrolytic, stranded, copper wire to DIN EN 60228 Class 2
Insulation: Halogen free cross linked polymeric compound
Core Identification: According to VG 95218 part 62
Covering of Cores: Halogen free compound or binder tape
Screen: Copper wire braiding screen with separating foil over braid
Outer Sheath: Halogen free, cross-linked elastomeric compound.

Construction: VG 95218 Part 62
Max Permissible Operating Voltage: AC 250V / DC 355V
AC Test Voltage: 2 kV
Working Temperature: -30°C / + 90°C
Min Bending Radius (Fixed): 5xD
General Requirements and Tests: VG 95218-2
Current Ratings: VG 95218-5
Flame Retardant: IEC 60332 /1, IEC 60332 / 3-24 Cat. C
Halogen Content: IEC 60754 / 1 – 2
Smoke Density: IEC 61034 / 1-2 ( DIN EN 50268/1-2)

Designation as per VG95218 Part.60 Dash No Cores x size Number of the single wires (min) Wall thickness of insulation nominal Wall thickness of sheath Outer Diameter (min- max.) Cable Weight Approx. Min. Bending Radius Fixed Installed Conductor resistance at (20ºC) (max) Insulation resistance (20ºC) (min)
No. x mm² mm mm mm mm kg/km mm (Ω/km) (MΩ·km)
A008 1x2x0,75 7 0.4 0.8 6 7.2 62 36 53.2 800
A003 6x2x0,75 7 0.4 1 10.8 12.5 230 63 53.2 800
A004 8x2x0,75 7 0.4 1 11.9 13.6 300 68 53.2 800
A005 10x2x0,75 7 0.4 1 13.7 15.4 335 77 53.2 800
A006 14x2x0,75 7 0.4 1 14.9 16.7 450 84 53.2 800
A007 16x2x0,75 7 0.4 1 16.1 18.1 505 91 53.2 800

 

We use cookies on our website to provide you a better experience. For detailed information please visit Our Cookie Policy and Clarification Text.