APPLICATION
Used as fixed installation cables in various electromechanical and electronic equipments of marine vehicles. Due to its’ overall screen the electromagnetic interference is minimized. Can be used as degaussing cable.
CONDUCTOR : Electrolytic, stranded, annealed copper wire. IEC 60228 Class 2 (tinned on request).
INSULATION : PVC insulation with Polyamide protective covering.
INNER SHEATH : PVC compound.
SEPARATOR : Water blocking tape.
SCREEN : Electrolytic copper braided screen (90% coverage).
OUTER SHEATH : Flame retardant, PVC based compound. Color: Green.
CONSTRUCTION : VG 88775
TESTS AND MATERIAL : VG 88775
FLAME RETARDATION : IEC 60332 /1, IEC 60332 / 3 Cat A
WORKING TEMPERATURE : – 20°C / + 85°C
MIN. BENDING RADIUS (FIXED) : 5 x (Overall Diameter)
RATED VOLTAGE : 500V
TEST VOLTAGE : 2,5kV
| CROSS SECTION (mm2) | OVERALL DIAMETER (mm) | APPX. WEIGHT (kg / km) | COPPER WEIGHT (kg / km) |
|---|---|---|---|
| 2×1,5 | 10 | 160 | 28.8 |
| 3×1,5 | 10.4 | 180 | 43.2 |
| 7×1,5 | 13.2 | 300 | 100.8 |
| 10×1,5 | 15.7 | 400 | 144 |
| 12×1,5 | 16.5 | 440 | 172.8 |
| 14×1,5 | 17.1 | 490 | 201.6 |
| 16×1,5 | 17.9 | 550 | 230.4 |
| 19×1,5 | 18.6 | 620 | 273.6 |
| 24×1,5 | 21.1 | 760 | 345.6 |
| 27×1,5 | 21.5 | 820 | 388.8 |
| 33×1,5 | 22.9 | 970 | 475.2 |
| 2×2,5 | 11.2 | 210 | 48 |
| 3×2,5 | 11.7 | 240 | 72 |
| 4×2,5 | 12.4 | 280 | 96 |