APPLICATION
Mainly used above and below deck of the ship as control and communication cables in radio, radar and information systems.
CONDUCTOR : Electrolytic, stranded, annealed copper wire IEC 60228 Class 2 (tinned on request).
INSULATION : PVC insulation with Polyamide protective covering.
QUADDING : Four cores formed into a star-quad and star-quads laid up concentrically.
INNER SHEATH : PVC compound.
SEPARATOR : Water blocking tape.
SCREEN : Electrolytic copper braided screen (90% coverage).
OUTER SHEATH : Flame retardant, PVC based compound. Color: Green.
CONSTRUCTION : VG 88777
TESTS AND MATERIAL : VG 88777
FLAME RETARDATION : IEC 60332 /1, IEC 60332 / 3 Cat A
WORKING TEMPERATURE : – 20°C / + 85°C
MIN. BENDING RADIUS (FIXED) : 7 x (Overall Diameter)
RATED VOLTAGE : 250 V
TEST VOLTAGE : 2,0 kV
| CROSS SECTION (mm2) | OVERALL DIAMETER (mm) | APPX. WEIGHT (kg / km) | COPPER WEIGHT (kg / km) |
|---|---|---|---|
| 2x2x0,75 | 9 | 155 | 28.8 |
| 4x2x0,75 | 13 | 270 | 57.6 |
| 10x2x0,75 | 18 | 505 | 144 |
| 14x2x0,75 | 19 | 570 | 201.6 |