Application
Used as fixed installation cables in various electromechanical and electronic equipments of marine vehicles,
in most areas & on open deck in ships.
* Minimum recommended installation temperature -15°C
For core identification, diameter tolerances and current ratings etc. see technical information section
CONDUCTOR : Electrolytic, stranded, annealed sector shaped copper wire to IEC 60228 Class 5 SM (Tinned on request)
INSULATION : Cross linked polyethylene compound (XLPE)
INNER COVERING : Separating foil
OUTER SHEATH : Halogen-free, flame retardant, UV resistant, polyolefin based compound (SHF 1)
COLOR : Black or Grey
CONSTRUCTION : IEC 60092 / 353
TESTS AND MATERIAL : IEC 60092 / 350-360
FLAME RETARDANT : IEC 60332 / 1, IEC 60332 / 3-22 Cat A
HALOGEN CONTENT : IEC 60754 / 1-2
SMOKE EMISSION : IEC 61034 / 1-2 (DIN EN 50268 / 1-2)
OZON RESISTANCE : IEC 60811 / 403
WORKING TEMPERATURE : -40°C / + 90°C
MIN. BENDING RADIUS (FIXED) : For cables D ≤ 25 mm 4xD, For cables D > 25 mm 6xD
RATED VOLTAGE : 0,6 / 1 kV
TEST VOLTAGE : 3,5 kV
UV AND SUNLIGHT RESISTANCE : EN 50289-4-17 A&B, ISO 4892-2&3
| Nominal Cross-Section (mm²) | Cable Outer Diameter (mm) | Approximate Cable Weight (kg/km) | Minimum bending radius (fixed) (mm) | Maximum Conductive Resistance at 20°C (ohms/km) | Current carrying capacity at 45°C (A) |
|---|---|---|---|---|---|
| 3×35 | 21.2 | 1125 | 128 | 0.554 | 107 |
| 3×50 | 25.6 | 1575 | 154 | 0.386 | 137 |
| 3×120 | 37.4 | 3640 | 225 | 0.161 | 233 |
| 3×150 | 41.3 | 4415 | 248 | 0.129 | 268 |
| 3×185 | 46 | 5350 | 276 | 0.106 | 303 |
| 3×240 | 51.5 | 7150 | 309 | 0.0801 | 356 |
| 4×35 | 25.1 | 1495 | 151 | 0.554 | 107 |
| 4×50 | 28.8 | 2045 | 173 | 0.386 | 137 |
| 4×70 | 33.7 | 2960 | 203 | 0.272 | 168 |
| 4×95 | 37 | 3760 | 222 | 0.206 | 201 |
| 4×120 | 41.3 | 4795 | 248 | 0.161 | 233 |
| 4×150 | 45.5 | 5795 | 273 | 0.129 | 268 |
| 4×185 | 51 | 7050 | 306 | 0.106 | 303 |
| 4×240 | 56.3 | 9420 | 338 | 0.0801 | 356 |