Search
Close this search box.

بحث

Search
Close this search box.

RG 58 C/U (CuSn/CuSn)

Certificates :

APPLICATIONS

These types of cables are used for antenna connections of CB, cordless systems and connection cables for
terminals and systems of data transmission networks. Halogen Free, Non Corrosive and Flame retardant, thanks
to the HFFR Compound that has been used on their construction.

Inner Conductor: 19 x 0,18 mm stranded tinned copper wire

Insulation: Solid Polyethylene compound

Screen: Tinned copper wire braiding

Outer Sheath: Halogen free flame retardant compound (SHF1)

Overall diameter: Ø 4,95 ± 0,20 mm

Cable Weight: 45 kg/km

Min. Bending radius: 45 mm

Max. Tensile Strength: 30 N

Operating Temperature: – 20°C / +70°C

Construction: EN 50117-1 (MIL-C-17)

Flame Retardant: EN 60332-1-2, IEC 60332-3-24

Halogen Content: IEC 60754-1/2, IEC 60684-2

Smoke Emission: IEC 61034-1/2

Max. Conductor Resistance: < 38,5 Ω / km

Min. Insulation Resistance: 1 GΩ x km

Capacitance: < 98 ± 4 pF / m

Capacitance Unbalance: 1600 pF / km

Impedance: 50 ± 2 Ω

Velocity of Propagation: 66%

Test Voltage: 5 kV

Operating Voltage: 1000 V

 

Attenuations at 20°C

10MHz: 4.70 dB / 100m

100MHz: 15.70 dB / 100m

200MHz: 23.00 dB / 100m

400MHz: 34.50 dB / 100m

1000MHz: 60.00 dB / 100m

 

 

 