EC200 SFTP HFFR

Certificates :

APPLICATIONS

IEEE 802.3: 10Base-T, 100Base-T, 1000Base-T, IEEE 802.5 16 MB, ISDN, TPDDI, ATM Power over Ethernet (PoE) / PoE+. These cables are used in data communication networks with 200 MHz bandwith capacity. And for the transmission of digital and analogue voice, video and signals on ships.

Conductor: 24 AWG Bare Copper

Insulation: PE compound

Overall Screen: Al-Pet Foil and Tinned Copper Wire Braiding

Sheath: Halogen free flame retardant compound (SHF1)

Overall diameter: Ø 6,20 ± 0,20 mm

Cable Weight: 48 kg/km

Min. Bending radius during draw in: 50 mm

Min. Bending radius permanently installed: 25 mm

Max. Tensile Strength: 90 N

Min. Crush Resistance: 1000 N/10 cm

Min. Impact: 10 Impacts

Installation Temperature: 0°C / +50°C

Operating Temperature: – 20°C / +70°C

Standarts: IEC 61156-5, EN 50288-2-1,

                     EN 50173-1, ISO/IEC 11801 2nd ed

Flame Retardant: IEC 60332-1-2, IEC 60332-3-24

Halogen Free: IEC 60684-2, IEC60754-1/2

Low Smoke: IEC 61034-1/2

Max. Conductor Resistance: < 9.5 Ω / km

Max. Resistance Unbalance: < 2 %

Min. Insulation Resistance: 5000 MΩ x m

Mutual Capacitance: < 60 pF / m

Capacitance Unbalance: 1600 pF / km

Impedance at 100 MHz: 100 ± 5 Ω

Velocity of Propagation: 66 %

Delay Skew: < 45 ns / 100 m

Test Voltage: 1000 V

Operating Voltage: 125 V

Nominal Transmission Characteristics at 20 °C
Frequency (MHz)Attenuation (dB/100 m)NEXT (dB)PS – NEXT (dB)ACR (dB/100 m)PS-ACR (dB/100 m)ACRF (dB/100 m)PS-ACRF (dB/100m)Return Loss (dB)
12.070676865787521
43.662595855706729
105.755525047524930
167.755524542504730
31.211.248454037353229
62.516.448453027353227
10020.940372017302727
20027.33532107201720