APPLICATION
Used for supplying excavating, crushing machines
and equipment.
CONDUCTOR : Electrolytic, stranded, tinned copper wire IEC 60228 Class 5
INSULATION : EPR
LAYUP : Cores are laid up over a cradle without contacting each other.
BEDDING : Rubber based bedding compound.
ARMOUR : Galvanized steel pliable armour.
OUTER SHEATH : Heavy duty chloroprene outer sheath.
RELATED STANDARDS : MGM 115/1985
RATED VOLTAGE : 600/1000 V
TEST VOLTAGE : 3 kV
Cross Section | 3×2,5 | 3×4 | 3×6 | 3×10 | 3×16 | 3×25 | 3×35 | 3×50 | 3×70 | 3×95 | 3×120 | 3×150 | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Phase and Earth Conductors | |||||||||||||
Number and cross section | mm2 | 3×2,5 | 3×4 | 3×6 | 3×10 | 3×16 | 3×25 | 3×35 | 3×50 | 3×70 | 3×95 | 3×120 | 3×150 |
Stranding | mm | 50/0,25 | 56/0,30 | 84/0,30 | 80/0,40 | 126/0,40 | 196/0,40 | 276/0,40 | 396/0,40 | 360/0,50 | 475/0,50 | 629/0,50 | 740/0,50 |
Conductor diameter | Nom. mm | 2.10 | 2.70 | 3.30 | 4.40 | 5.50 | 7.10 | 8.40 | 10.10 | 11.90 | 13.90 | 15.80 | 17.00 |
Insulation thickness | mm | 1.4 | 1.4 | 1.5 | 1.5 | 1.5 | 1.6 | 1.6 | 1.7 | 1.8 | 2.0 | 2.2 | 2.3 |
Cable details | |||||||||||||
Radial thickness of inner sheath | mm | 2.0 | 2.0 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 3.8 | 3.8 | 5.0 |
Size of armour | mm | 7/0,45 | 7/0,45 | 7/0,71 | 7/0,71 | 7/0,71 | 7/0,90 | 7/0,90 | 7/0,90 | 7/0,90 | 7/0,90 | 7/0,90 | 7/1,25 |
Outer sheath thickness | mm | 2.5 | 2.5 | 3.8 | 3.8 | 3.8 | 4.0 | 4.3 | 4.7 | 5.2 | 5.8 | 6.2 | 6.6 |
Min. overall diameter | mm | 24.5 | 25.8 | 34.3 | 36.2 | 38.6 | 43.6 | 46.6 | 51.3 | 56.6 | 68.4 | 72.2 | 83.3 |
Max. overall diameter | mm | 26.9 | 28.2 | 36.5 | 38.4 | 40.8 | 47.0 | 50.6 | 56.7 | 62.7 | 72.1 | 77.0 | 87.3 |
Min. bending radius | mm | 243 | 254 | 329 | 346 | 368 | 423 | 456 | 511 | 565 | 649 | 693 | 786 |
Appx. cable weight | kg/km | 990 | 1.15 | 2 | 2.35 | 2.75 | 3.35 | 4.3 | 5.32 | 6.75 | 8.75 | 10.65 | 12.5 |
Copper weight | kg/km | 72 | 115 | 173 | 288 | 461 | 720 | 1.008 | 1.44 | 2.016 | 2.736 | 3.456 | 4.32 |
Electrical details | |||||||||||||
«Continuous current rating at 25°C Ambient» | A | 28 | 37 | 46 | 63 | 85 | 110 | 135 | 170 | 205 | 250 | 295 | 320 |
Max. DC resistance at 20°C | |||||||||||||
Phase and earth conductors | Ω /km | 8.21 | 5.09 | 3.39 | 1.95 | 1.24 | 0.795 | 0.565 | 0.393 | 0.277 | 0.210 | 0.164 | 0.132 |
Armour | Ω /km | 4.6 | 4.2 | 2.2 | 2.0 | 1.9 | 1.3 | 1.2 | 1.1 | 0.94 | 0.80 | 0.74 | 0.45 |