Мы используем файлы cookie на нашем веб-сайте, чтобы вам было удобнее работать. Для получения подробной информации посетите Политику использования файлов cookie. и вы можете просмотреть наш текст пояснения.
Application
These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply. Recomended for use protection needed against aliphatic and aromatic hydrocarbons, engine oils and other organic and inorganic chemicals. This multi layer barrier provide also excellent protection against corrosion and moisture.
Available Features on Request
• 300 V version
• Yv type reinforced sheath
• HDPE outher sheath alternative
• Hydrocarbon resistant
• Anti termit / anti rodent
• PE insulation
• Oil resistant
• LSF (Low Smoke) version
• PE Sheath
• UV resistant
• Fire resistant version
CONDUCTOR : Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)
INSULATION: XLPE compound to EN50290-2-29 Black / White twisted pairs with numbered cores
BINDER TAPE :Polyester foil on each twisted pair
INDIVİDUAL SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
BINDER TAPE : Polyester foil on overall cable core formed by stranded pairs
COLLECTIVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
INNER SHEATH :PVC compound to EN50290-2-22
CHEMICAL & MOISTURE BARRIER (MULTI LAYER SHEATH) :Longitudinally applied protective plastic coated Aluminum tape bonded with an extruded layer of high density polyethylene (HDPE) to 50290-2-4 and plus an additional extruded layer of Polyamide (PA)
ARMOUR :Round galvanised steel wires EN 10257-1
OUTER SHEATH :Flame retardant PVC compound to EN50290-2-22 Black colour. Other colours on request
RATED VOLTAGE :500 V a.c.
AC TEST VOLTAGE :2000 V x 1 min. (core:core / core: screen)
WORKING TEMPERATURE :-40°C / + 90°C (during operation) – 5 °C / + 50°C (during installation)
MIN BENDING RADIUS (FIXED) :10 x D
CONSTRUCTION :EN 50288-7
MATERIAL TYPES & TESTS :EN 50290-2 series
ELECTRICAL & MECHANICAL TESTS :EN 50289 series
FLAME RETARDANT :IEC 60332 / 1-2, IEC 60332 / 3-24 Cat C
Авторские права © 2024 ÜNTEL KABLOLARI. Все права защищены.