APPLICATIONS
These types of cables are used for antenna connections of CB, cordless systems and connection cables for terminals
and systems of data transmission networks. These cables are Halogen Free, Non Corrosive and Flame retardant,
thanks to the HFFR Compound that has been used on their construction.
Inner Conductor: 7×0.75 mm stranded bare copper wire
Insulation: Solid Polyethylene compound
Screen: Copper wire braiding
Outer Sheath: Halogen free flame retardant compound (SHF1)
Overall diameter: Ø 10,30 ± 0,20 mm
Cable Weight: 185 kg/km
Min. Bending Radius: 85 mm
Max. Tensile Strength: 30 N
Operating Temperature: — 20°C / +70°C
Construction: EN 50117-2-4 (MIL-C-17)
Flame Retardant: EN 60332-1-2, IEC 60332-3-24
Halogen Content: IEC 60754-1/2, IEC 60684-2
Smoke Emission: IEC 61034-1/2
Max. Conductor Resistance: < 6,0 Ω / km
Min. Insulation Resistance: 2 GΩ x km
Capacitance: < 100 ± 3 pF / m
Impedance: 50 ± 2 Ω
Velocity of Propagation: 66 %
Test Voltage: 5 kV
Operating Voltage: 1000 V
Attenuations at 20°C
50 MHz: 4.50 dB / 100m
100 MHz: 6.70 dB / 100m
200 MHz: 9.90 dB / 100m
400 MHz: 14.30 dB / 100m
500 MHz: 16.10 dB / 100m
1000 MHz: 24.30 dB / 100m