UNT EVC CABLE Type 126 (DC)

Certificates :

APPLICATION

These cables suitable for trailing EV plug connections to vehicle.
The charging cables are applicable for charging mode 4 of EN 61851-1.

CONDUCTOR: Electrolytic annealed, class 5 stranded plain copper wires IEC 60228 (tinned conductor on request)
INSULATION: Special compound type EVI-2 according to IEC 62893-1
OUTER SHEATH:Special compound type EVM-1, as specified in IEC 62893-1
COLOR: Black (other colors available on request)

RATED VOLTAGE DC: 1,5 kV
RATED VOLTAGE AC: 0,6/1 kV
OPERATING TEMPERATURE: -40°C to +90°C
CONDUCTOR OPERATING TEMPERATURE: Max. 90°C
MIN. INSTALLATION TEMPERATURE: -25°C
MAX. STORAGE TEMPERATURE: 45°C
MIN. BENDING RADIUS: EN 50565-1 Tab.3
FREE MOVEMENT D≤12 MM: 5 x D mm
FREE MOVEMENT D>12 MM: 6 x D mm
CURRENT CARRYING CAPACITIES: IEC 60364-5-52

CONDUCTOR SHORT-CIRCUIT TEMPERATURE
BARE COPPER: 250°C (Max. 5 s)
TINNED COPPER: 200°C (Max. 5 s)

Number of cores x cross section (mm²)Insulation Thickness nom. (mm)Outer Sheath Thickness nom. (mm)Outer Sheath Diameter min. (mm)Outer Sheath Diameter max. (mm)App. Weight (kg/km)Min. Bending Radius Free Movement (mm)
2×50+1G25+4x(2×0,75)1,1 — 1 — 0,42,227,934,81595209
2×70+1G35+4x(2×0,75)1,2 — 1 — 0,42,532,640,72220244
4×50+1G25+4x(2×0,75)1,1 — 1 — 0,42,736412845246