Application
These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.
Available Features on Request
• 300 V version
• Multi core / Multi triple / Multi quad
• Hydrocarbon resistant
• Oil resistant
• Hv type reinforced sheath
• Anti termit / anti rodent
• UV resistant
CONDUCTOR :Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)
INSULATION :XLPE compound to EN50290-2-29 Black / White twisted pairs with numbered cores
BINDER TAPE :Polyester foil on overall cable core formed by stranded pairs.
COLLECTIVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
OUTER SHEATH :Halogen free flame retardant LSZH compound to EN50290-2-27 Blue for intrinsically safe cable Black for UV resistant and/or non-instrinsically safe cable Gray for indoor applications Other colours on request
RATED VOLTAGE :500 V a.c.
AC TEST VOLTAGE :2000 V x 1 min. (core:core / core: screen)
WORKING TEMPERATURE :-40°C / + 90°C (during operation) – 5 °C / + 50°C (during installation)
MIN BENDİNG RADIUS (FIXED) :7,5 x D
CONSTRUCTION :EN 50288-7
MATERIAL TYPES & TESTS :EN 50290-2 series
ELECTRICAL & MECHANICAL TESTS :EN 50289 series
FLAME RETARDANT :IEC 60332 / 1-2, IEC 60332 / 3-24 Cat C
HALOGEN CONTENT :IEC 60754 / 1-2
SMOKE EMISSION :IEC 61034 / 1-2
Conductor size (Class 2) | nom. | mm2 | 0.5 | 0.75 | 1 | 1.3 | 1.5 | 2.5 |
---|---|---|---|---|---|---|---|---|
Conductor resistance | max. | Ω/km | 36.7 | 25 | 18.5 | 14.2 | 12.3 | 7.6 |
Insulation resistance | min. | MΩxkm | 5000 | |||||
Mutual Capacitance | max. | nF/km | 150 | |||||
Inductance | max. | mH/km | 1 | |||||
L/R ratio | max. | µH/Ω | 25 | 25 | 25 | 40 | 40 | 60 |
(*) At 20 °C |
Cross Sections (mm2) | Nominal Overall Diameter (mm) | Approximate Weight (kg/km) |
---|---|---|
1x2x0,5 | 6 | 44 |
2x2x0,5 | 8.8 | 76 |
4x2x0,5 | 10.3 | 115 |
5x2x0,5 | 11.2 | 134 |
6x2x0,5 | 12.1 | 153 |
8x2x0,5 | 13.7 | 196 |
10x2x0,5 | 15.6 | 241 |
12x2x0,5 | 16.1 | 272 |
16x2x0,5 | 17.8 | 338 |
20x2x0,5 | 20 | 416 |
24x2x0,5 | 22.2 | 495 |
1x2x0,75 | 6.7 | 54 |
2x2x0,75 | 10 | 98 |
4x2x0,75 | 11.5 | 146 |
5x2x0,75 | 12.7 | 177 |
6x2x0,75 | 13.8 | 204 |
8x2x0,75 | 15.6 | 261 |
10x2x0,75 | 17.6 | 313 |
12x2x0,75 | 18.4 | 365 |
16x2x0,75 | 20.3 | 456 |
20x2x0,75 | 22.8 | 562 |
24x2x0,75 | 25.4 | 671 |
1x2x1 | 6.9 | 59 |
2x2x1 | 10.3 | 108 |
4x2x1 | 11.9 | 165 |
5x2x1 | 13.1 | 201 |
6x2x1 | 14.3 | 233 |
8x2x1 | 16.2 | 300 |
10x2x1 | 18.4 | 370 |
12x2x1 | 19 | 420 |
16x2x1 | 21.3 | 540 |
20x2x1 | 23.9 | 665 |
24x2x1 | 26.6 | 793 |
1x2x1,3 | 7.5 | 72 |
2x2x1,3 | 10.9 | 126 |
4x2x1,3 | 12.9 | 204 |
5x2x1,3 | 14 | 242 |
6x2x1,3 | 15.4 | 288 |
8x2x1,3 | 17.3 | 362 |
10x2x1,3 | 19.7 | 448 |
12x2x1,3 | 20.4 | 514 |
16x2x1,3 | 22.8 | 664 |
20x2x1,3 | 25.6 | 820 |
24x2x1,3 | 28.5 | 977 |
1x2x1,5 | 7.7 | 76 |
2x2x1,5 | 11.3 | 135 |
4x2x1,5 | 13.3 | 220 |
5x2x1,5 | 14.5 | 262 |
6x2x1,5 | 15.9 | 312 |
8x2x1,5 | 18.1 | 403 |
10x2x1,5 | 20.4 | 488 |
12x2x1,5 | 21.3 | 571 |
16x2x1,5 | 23.8 | 736 |
20x2x1,5 | 26.7 | 908 |
24x2x1,5 | 29.7 | 1083 |
1x2x2,5 | 8.9 | 103 |
2x2x2,5 | 13.4 | 193 |
4x2x2,5 | 15.9 | 324 |
5x2x2,5 | 17.3 | 387 |
6x2x2,5 | 19.1 | 461 |
8x2x2,5 | 21.7 | 597 |
10x2x2,5 | 24.7 | 738 |
12x2x2,5 | 25.6 | 853 |
16x2x2,5 | 28.6 | 1105 |
20x2x2,5 | 32.3 | 1380 |
24x2x2,5 | 36 | 1646 |