APPLICATIONS
These types of cables are used for antenna connections of CB, cordless systems and connection cables for terminals
and systems of data transmission networks. These cables are Halogen Free, Non Corrosive and Flame retardant,
thanks to the HFFR Compound that has been used on their construction.
Inner Conductor: 7×0.75 mm stranded silver coated copper wire
Insulation: Solid Polyethylene compound
Screen 1: Aluminium/poleysther/aluminium tape
Screen 2: Silver coated copper wire braiding
Outer Sheath: Halogen free flame retardant compound (SHF1)
Overall diameter: Ø 10,90 ± 0,20 mm
Cable Weight: 228 kg/km
Min. Bending Radius: 90 mm
Max. Tensile Strength: 30 N
Operating Temperature: – 20°C / +70°C
Construction: EN 50117 (MIL-C-17)
Flame Retardant: EN 60332-1-2, IEC 60332-3-242
Halogen Content: IEC 60754-1/2, IEC 60684-2
Smoke Emission: IEC 61034-1/2
Max. Conductor Resistance: < 6,0 Ω / km
Min. Insulation Resistance: 2 GΩ x km
Capacitance: < 100 ± 3 pF / m
Impedance: 50 ± 2 Ω
Velocity of Propagation: 66 %
Test Voltage: 5 kV
Operating Voltage: 1000 V
Attenuations at 20°C
10 MHz: 2.00 dB / 100m
50 MHz: 4.30 dB / 100m
100 MHz: 6.00 dB / 100m
200 MHz: 8.20 dB / 100m
300 MHz: 10.10 dB / 100m
500 MHz: 13.50 dB / 100m
1000 MHz: 20.30 dB / 100m
2500 MHz: 37.40 dB / 100m