Accueil » Câbles DataMarin » EC400 SFTP HFFR

EC400 SFTP HFFR

Certificates :

APPLICATIONS

IEEE 802.3: 10Base-T, 100Base-T, 1000Base-T, IEEE 802.5 16 MB, ISDN, TPDDI, ATM Power over Ethernet (PoE) / PoE+. These cables are used in data communication networks and for the transmission of digital and analogue voice, video and signals on ships.

Conductor: 23 AWG Bare Copper

Insulation: PE compound

Central Cross: Halogen free separator

Overall Screen: Al-Pet Foil and Tinned Copper Wire Braiding

Sheath: Halogen free flame retardant compound (SHF1)

Overall diameter: Ø 7,10 ± 0,20 mm

Cable Weight: 64 kg/km

Min. Bending radius during draw in: 60 mm

Min. Bending radius permanently installed: 30 mm

Max. Tensile Strength: 90 N

Min. Crush Resistance: 1000 N/10 cm

Min. Impact: 10 Impacts

Installation Temperature: 0°C / +50°C

Operating Temperature: – 20°C / +70°C

Standarts: IEC 61156-5, EN 50288-5-1,

                     EN 50173-1, ISO/IEC 11801 2nd ed

Flame Retardant: IEC 60332-1-2, IEC 60332-3-24

Halogen Free: IEC 60684-2, IEC60754-1/2

Low Smoke: IEC 61034-1/2

Max. Conductor Resistance: < 9.5 Ω / km

Max. Resistance Unbalance: < 2 %

Min. Insulation Resistance: 5000 MΩ x m

Mutual Capacitance: < 60 pF / m

Capacitance Unbalance: 1600 pF / km

Impedance at 100 MHz: 100 ± 5 Ω

Velocity of Propagation: 66 %

Delay Skew: < 45 ns / 100 m

Coupling Attenuation: > 70 Db

Transfer Impedance at

1 / 10 / 30 MHz: < 10 / 10 / 30 mΩ / m

Segragation Class: C

Test Voltage: 1000 V

Operating Voltage: 125 V

Nominal Transmission Characteristics at 20 °C
Frequency (MHz)Attenuation (dB/100 m)NEXT (dB)PS – NEXT (dB)ACR (dB/100 m)PS-ACR (dB/100 m)ACRF (dB/100 m)PS-ACRF (dB/100m)Return Loss (dB)
1283808582838025
43.673707067706731
10673706562605730
10019.555524037353225
20028.550472522302722
2503245422522221922
3003340371512201722
400394037174201720