Usamos cookies en nuestro sitio web para brindarle una mejor experiencia. Para obtener información detallada, visite nuestra Política de cookies y el texto aclaratorio.
APPLICATION
Used in coal mines to supply cutters and drills. Monitoring cores make easy to detect outer damages.
CONDUCTOR : Electrolytic, stranded, tinned copper wire DiN VDE 0295 Class 5
SEPERATOR : Semiconducting layer over monitoring conductor
INSULATION : Phase and control cores are insulated with 3Gl3 compound (acc. to DiN VDE 0207 part 20). Monitoring core is not insulated.
SEPERATOR : Semiconducting layer over phase cores and control units
LAYUP : Phase cores are laid up in contact with each other and control units which were laid up beforehand.
BEDDING : Special elastomeric compound GM/b (acc. to DiN VDE 0207 Teil 21)
ARMOUR : Galvanized steel and tinned copper pliable armour
OUTER SHEATH : Heavy duty elastomer outer sheath 5GM5 (acc. to DiN VDE 0207 Teil 21)
RELA TED STANDARDS : VDE 0250- 812
RATED VOLTAGE : 06/1 kV
TEST VOLTAGE : 3 kV
Cross section (mm2) | Min. overall diameter (mm) | Max. overall diameter (mm) | Approx. cable weight (kg/km) | Copper weight (kg/km) |
---|---|---|---|---|
3×16/16kon + 2×2,5St + 2,5UEL | 33 | 38 | 2,000 | 690 |
3×25/16kon + 3x(2×1,5St + 1,5UEL) | 41 | 46 | 3,000 | 1,050 |
3×35/16kon + 3x(2×1,5St + 1,5UEL) | 41 | 46 | 3,200 | 1,350 |
3×50/25kon + 3x(2×1,5St + 1,5UEL) | 46 | 51 | 4,200 | 1,870 |
3×70/35kon + 3x(2×1,5St + 1,5UEL) | 50 | 55 | 5,400 | 2,550 |
3×95/50kon + 3x(2×1,5St + 1,SUEL) | 57 | 62 | 6,900 | 3,410 |
3x12000kon + 3x(2×1,5St+ 1,SUEL.) | 62 | 67 | 8,600 | 4,330 |
Copyright © 2024 ÜNTEL KABLOLARI. Todos los derechos se quedan reservados.