Usamos cookies en nuestro sitio web para brindarle una mejor experiencia. Para obtener información detallada, visite nuestra Política de cookies y el texto aclaratorio.
Application
These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.
Available Features on Request
• 300 V version
• Yw 105ºC version
• Hydrocarbon resistant
• Yv type reinforced sheath
• Oil resistant
• Anti termit / anti rodent
• UV resistant
• LSF (Low Smoke) version
CONDUCTOR :Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)
INSULATION :PVC compound to EN50290-2-21 Black / White / Red twisted triads with numbered cores
BINDER TAPE :Polyester foil on each twisted triad
INDIVIDUAL SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
BINDER TAPE :Polyester foil on overall cable core formed by stranded triples
COLLECTIVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
OUTER SHEATH :Flame retardant PVC compound to EN50290-2-22 Blue for intrinsically safe cable Black for UV resistant and/or non-instrinsically safe cable Other colours on request
RATED VOLTAGE :500 V a.c.
AC TEST VOLTAGE :2000 V x 1 min. (core:core / core: screen)
WORKING TEMPERATURE : -30°C / + 70°C (during operation) – 5 °C / + 50°C (during installation)
MIN BENDING RADIUS (FIXED) :7,5 x D
CONSTRUCTION :EN 50288-7
MATERIAL TYPES & TESTS :EN 50290-2 series
ELECTRICAL & MECHANICAL TESTS :EN 50289 series
FLAME RETARDANT :IEC 60332 / 1-2, IEC 60332 / 3-24 Cat C
Conductor size (Class 2) | nom. | mm2 | 0.5 | 0.75 | 1 | 1.3 | 1.5 | 2.5 |
---|---|---|---|---|---|---|---|---|
Conductor resistance | max. | Ω/km | 36.7 | 25 | 18.5 | 14.2 | 12.3 | 7.6 |
Insulation resistance | min. | MΩxkm | 100 | |||||
Mutual Capacitance | max. | nF/km | 250 | |||||
Inductance | max. | mH/km | 1 | |||||
L/R ratio | max. | µH/Ω | 25 | 25 | 25 | 40 | 40 | 60 |
(*) At 20 °C |
Cross Sections (mm2) | Nominal Overall Diameter (mm) | Approximate Weight (kg/km) |
---|---|---|
2x3x0,5 | 11 | 123 |
4x3x0,5 | 13 | 201 |
5x3x0,5 | 14.2 | 240 |
6x3x0,5 | 15.6 | 285 |
8x3x0,5 | 17.5 | 360 |
10x3x0,5 | 20.1 | 447 |
12x3x0,5 | 20.9 | 523 |
16x3x0,5 | 23.4 | 675 |
20x3x0,5 | 26.3 | 832 |
24x3x0,5 | 29.3 | 994 |
2x3x0,75 | 12.1 | 150 |
4x3x0,75 | 14.4 | 251 |
5x3x0,75 | 15.9 | 307 |
6x3x0,75 | 17.3 | 358 |
8x3x0,75 | 19.7 | 464 |
10x3x0,75 | 22.5 | 575 |
12x3x0,75 | 23.5 | 674 |
16x3x0,75 | 26.3 | 871 |
20x3x0,75 | 29.5 | 1075 |
24x3x0,75 | 32.9 | 1284 |
2x3x1 | 12.7 | 172 |
4x3x1 | 14.8 | 280 |
5x3x1 | 16.4 | 344 |
6x3x1 | 18.1 | 410 |
8x3x1 | 20.3 | 521 |
10x3x1 | 23.5 | 659 |
12x3x1 | 24.3 | 761 |
16x3x1 | 27.2 | 986 |
20x3x1 | 30.5 | 1217 |
24x3x1 | 34.2 | 1471 |
2x3x1,3 | 13.5 | 200 |
4x3x1,3 | 15.9 | 338 |
5x3x1,3 | 17.4 | 407 |
6x3x1,3 | 19.2 | 486 |
8x3x1,3 | 21.8 | 631 |
10x3x1,3 | 25 | 784 |
12x3x1,3 | 26 | 921 |
16x3x1,3 | 29.1 | 1195 |
20x3x1,3 | 32.7 | 1477 |
24x3x1,3 | 36.5 | 1764 |
2x3x1,5 | 14 | 214 |
4x3x1,5 | 16.6 | 366 |
5x3x1,5 | 18.4 | 450 |
6x3x1,5 | 20.1 | 526 |
8x3x1,5 | 22.8 | 684 |
10x3x1,5 | 26.3 | 962 |
12x3x1,5 | 27.2 | 1000 |
16x3x1,5 | 30.5 | 1300 |
20x3x1,5 | 34.4 | 1621 |
24x3x1,5 | 38.4 | 1936 |
2x3x2,5 | 16.7 | 304 |
4x3x2,5 | 19.8 | 528 |
5x3x2,5 | 21.9 | 650 |
6x3x2,5 | 24.1 | 775 |
8x3x2,5 | 27.4 | 1010 |
10x3x2,5 | 31.6 | 1267 |
12x3x2,5 | 32.7 | 1473 |
16x3x2,5 | 36.8 | 1935 |
20x3x2,5 | 41.3 | 2391 |
24x3x2,5 | 46.3 | 2877 |