Usamos cookies en nuestro sitio web para brindarle una mejor experiencia. Para obtener información detallada, visite nuestra Política de cookies y el texto aclaratorio.
Application
These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.
Available Features on Request
• 300 V version
• Yv type reinforced sheath
• Hydrocarbon resistant
• Anti termit / anti rodent
• Oil resistant
• LSF (Low Smoke) version
• UV resistant
CONDUCTOR :Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)
INSULATİON :XLPE compound to EN50290-2-29 Black / White / Red twisted triads with numbered cores
BİNDER TAPE :Polyester foil on each twisted triad
INDİVİDUAL SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
BİNDER TAPE :Polyester foil on overall cable core formed by stranded pairs
COLLECTİVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
INNER SHEATH :PVC compound to EN50290-2-22
ARMOUR :Round galvanised steel wires to EN 10257-1
OUTER SHEATH :Flame retardant PVC compound to EN50290-2-22 Blue for intrinsically safe cable Black for UV resistant and/or non-instrinsically safe cable Other colours on request
RATED VOLTAGE :500 V a.c.
AC TEST VOLTAGE :2000 V x 1 min. (core:core / core: screen)
WORKİNG TEMPERATURE :-40°C / + 90°C (during operation) – 5 °C / + 50°C (during installation)
MİN BENDİNG RADİUS (FİXED) :10 x D
CONSTRUCTİON :EN 50288-7
MATERİAL TYPES & TESTS :EN 50290-2 series
ELECTRİCAL & MECHANİCAL TESTS :EN 50289 series
FLAME RETARDANT :IEC 60332 / 1-2, IEC 60332 / 3-24 Cat C
Conductor size (Class 2) | nom. | mm2 | 0.5 | 0.75 | 1 | 1.3 | 1.5 | 2.5 |
---|---|---|---|---|---|---|---|---|
Conductor resistance | max. | Ω/km | 36.7 | 25 | 18.5 | 14.2 | 12.3 | 7.6 |
Insulation resistance | min. | MΩxkm | 5000 | |||||
Mutual Capacitance | max. | nF/km | 150 | |||||
Inductance | max. | mH/km | 1 | |||||
L/R ratio | max. | µH/Ω | 25 | 25 | 25 | 40 | 40 | 60 |
(*) At 20 °C |
Cross Sections (mm2) | Nominal Overall Diameter (mm) | Approximate Weight (kg/km) |
---|---|---|
2x3x0,5 | 15.6 | 402 |
4x3x0,5 | 17.6 | 517 |
5x3x0,5 | 18.8 | 580 |
6x3x0,5 | 20.7 | 752 |
8x3x0,5 | 22.8 | 814 |
10x3x0,5 | 25.4 | 1038 |
12x3x0,5 | 26 | 1109 |
16x3x0,5 | 28.3 | 1308 |
20x3x0,5 | 31.2 | 1526 |
24x3x0,5 | 35.3 | 1992 |
2x3x0,75 | 16.7 | 454 |
4x3x0,75 | 19 | 591 |
5x3x0,75 | 21 | 784 |
6x3x0,75 | 22.6 | 878 |
8x3x0,75 | 24.8 | 1028 |
10x3x0,75 | 27.6 | 1207 |
12x3x0,75 | 28.4 | 1309 |
16x3x0,75 | 31.2 | 1563 |
20x3x0,75 | 35.5 | 2067 |
24x3x0,75 | 38.9 | 2378 |
2x3x1 | 17.1 | 477 |
4x3x1 | 19.4 | 632 |
5x3x1 | 21.7 | 843 |
6x3x1 | 23.2 | 935 |
8x3x1 | 25.6 | 1110 |
10x3x1 | 28.4 | 1302 |
12x3x1 | 29.4 | 1432 |
16x3x1 | 33 | 1900 |
20x3x1 | 36.7 | 2262 |
24x3x1 | 40.2 | 2600 |
2x3x1,3 | 18.1 | 527 |
4x3x1,3 | 21 | 816 |
5x3x1,3 | 22.7 | 930 |
6x3x1,3 | 24.3 | 1043 |
8x3x1,3 | 26.9 | 1243 |
10x3x1,3 | 30.1 | 1473 |
12x3x1,3 | 31 | 1610 |
16x3x1,3 | 35.1 | 2190 |
20x3x1,3 | 38.7 | 2571 |
24x3x1,3 | 42.5 | 2958 |
2x3x1,5 | 18.6 | 554 |
4x3x1,5 | 21.9 | 877 |
5x3x1,5 | 23.5 | 986 |
6x3x1,5 | 25.4 | 1118 |
8x3x1,5 | 27.9 | 1328 |
10x3x1,5 | 31.2 | 1572 |
12x3x1,5 | 33 | 1923 |
16x3x1,5 | 36.7 | 2348 |
20x3x1,5 | 40.4 | 2753 |
24x3x1,5 | 45.2 | 3482 |
2x3x2,5 | 22 | 822 |
4x3x2,5 | 25.1 | 1109 |
5x3x2,5 | 27 | 1273 |
6x3x2,5 | 29.2 | 1442 |
8x3x2,5 | 33.2 | 1935 |
10x3x2,5 | 37.6 | 2348 |
12x3x2,5 | 38.7 | 2575 |
16x3x2,5 | 43.4 | 3401 |
20x3x2,5 | 48.5 | 4067 |
24x3x2,5 | 53.3 | 4708 |
Copyright © 2024 ÜNTEL KABLOLARI. Todos los derechos se quedan reservados.