We use cookies on our website to provide you a better experience. For detailed information please visit our Cookie Policy and Clarification Text.
APPLICATION
Used in coal mines to supply cutters and drills. Monitoring cores make easy to detect outer damages.
CONDUCTOR : Electrolytic, stranded, tinned copper wire DiN VDE 0295 Class 5
SEPERATOR : Semiconducting layer over monitoring conductor
INSULATION : Phase and control cores are insulated with 3Gl3 compound (acc. to DiN VDE 0207 part 20). Monitoring core is not insulated.
SEPERATOR : Semiconducting layer over phase cores and control units
LAYUP : Phase cores are laid up in contact with each other and control units which were laid up beforehand.
BEDDING : Special elastomeric compound GM/b (acc. to DiN VDE 0207 Teil 21)
ARMOUR : Galvanized steel and tinned copper pliable armour
OUTER SHEATH : Heavy duty elastomer outer sheath 5GM5 (acc. to DiN VDE 0207 Teil 21)
RELA TED STANDARDS : VDE 0250- 812
RATED VOLTAGE : 06/1 kV
TEST VOLTAGE : 3 kV
Cross section (mm2) | Min. overall diameter (mm) | Max. overall diameter (mm) | Approx. cable weight (kg/km) | Copper weight (kg/km) |
---|---|---|---|---|
3×16/16kon + 2×2,5St + 2,5UEL | 33 | 38 | 2,000 | 690 |
3×25/16kon + 3x(2×1,5St + 1,5UEL) | 41 | 46 | 3,000 | 1,050 |
3×35/16kon + 3x(2×1,5St + 1,5UEL) | 41 | 46 | 3,200 | 1,350 |
3×50/25kon + 3x(2×1,5St + 1,5UEL) | 46 | 51 | 4,200 | 1,870 |
3×70/35kon + 3x(2×1,5St + 1,5UEL) | 50 | 55 | 5,400 | 2,550 |
3×95/50kon + 3x(2×1,5St + 1,SUEL) | 57 | 62 | 6,900 | 3,410 |
3x12000kon + 3x(2×1,5St+ 1,SUEL.) | 62 | 67 | 8,600 | 4,330 |