We use cookies on our website to provide you a better experience. For detailed information please visit our Cookie Policy and Clarification Text.
APPLICATION
Used for supplying excavating, crushing machines and equipment.
CONDUCTOR : Electrolytic, stranded, tinned copper wire IEC 60228 Class 5
SEPERATOR : Semiconduct ing layer
INSULATION : EPR (Ground core is not insulated in T‹P 320)
SEPERATOR : Semiconducting layer
SCREEN : Tinned copper / Nylon braided screen over insulated cores.
LAYUP : All cores are laid up in contact with each other.
BEDDING : Rubber based bedding compound.
ARMOUR : Galvanized steel pliable armour.
SEPERATOR : Galvanized steel tape or water blocking tape (optional)
OUTER SHEATH : Heavy duty chloroprene outer sheath.
RELATED STANDARDS : MGM 111/1985
RATED VOLTAGE : 1900/3300 V
TEST VOLTAGE : 7,5 kV
Cross Section | 3×16+16 | 3×25+16 | 3×35+16 | 3×50+25 | 3×70+35 | 3×95+50 | 3×120+70 | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MGM 111 TYPE 320 | |||||||||||||||
Phase Conductor | |||||||||||||||
Number and cross section | mm2 | 3×16 | 3×25 | 3×35 | 3×50 | 3×70 | 3×95 | 3×120 | |||||||
Stranding | mm | 126/0,40 | 196/0,40 | 276/0,40 | 396/0,40 | 360/0,50 | 475/0,50 | 608/0,50 | |||||||
Insulation thickness | mm | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 | |||||||
Earth Conductor | |||||||||||||||
Number and cross section | mm2 | 1×16 | 1×16 | 1×16 | 1×25 | 1×35 | 1×50 | 1×70 | |||||||
Stranding | mm | 126/0,40 | 126/0,40 | 126/0,40 | 196/0,40 | 276/0,40 | 396/0,40 | 360/0,50 | |||||||
Insulation thickness | mm | – | – | – | – | – | – | – | |||||||
Cable details | |||||||||||||||
Radial thickness of inner sheath | mm | 2.5 | 2.5 | 3.5 | 3.8 | 3.8 | 5.0 | 5.0 | |||||||
Size of armour | mm | 7/0,7 | 7/0,7 | 7/0,9 | 7/0,9 | 7/0,9 | 7/1,25 | 7/1,25 | |||||||
Radial thickness of outer sheath | mm | 4.0 | 5.0 | 5.3 | 5.8 | 6.7 | 6.8 | 7.2 | |||||||
Min. overall diameter | mm | 51.5 | 56.7 | 60.7 | 68.6 | 74.7 | 85.3 | 88.5 | |||||||
Max. overall diameter | mm | 55.8 | 60.1 | 64.1 | 72.3 | 78.4 | 89.2 | 93.7 | |||||||
Min. bending radius | mm | 503 | 541 | 577 | 651 | 706 | 803 | 844 | |||||||
Appx. cable weight | kg/km | 4.7 | 6.15 | 7.3 | 9.1 | 11 | 11.8 | 16.7 | |||||||
Copper weight | kg/km | 990 | 1.3 | 1.65 | 2.25 | 3.15 | 4.2 | 5.05 | |||||||
Electrical details | |||||||||||||||
“Continuous current rating at 25°C Ambient” | A | 85 | 110 | 135 | 170 | 205 | 250 | 295 | |||||||
Max. DC resistance at 20°C | |||||||||||||||
Phase Conductor | Ω /km | 1.24 | 0.795 | 0.565 | 0.393 | 0.277 | 0.21 | 0.164 | |||||||
3 screens and earth in parallel connection | Ω /km | 0.70 | 0.60 | 0.50 | 0.50 | 0.34 | 0.28 | 0.18 | |||||||
Armour | Ω /km | 1.40 | 0.96 | 0.90 | 0.79 | 0.73 | 0.47 | 0.44 | |||||||
Nominal Kesit | 4×16 | 4×25 | 4×35 | 4×50 | 4×70 | 4×95 | 4×120 | 4×150 | |||||||
MGM 111 TYPE 321 | |||||||||||||||
Conductors | |||||||||||||||
Number and cross section | mm2 | 4×16 | 4×25 | 4×35 | 4×50 | 4×70 | 4×95 | 4×120 | 4×150 | ||||||
Stranding | mm | 126/0,40 | 196/0,40 | 276/0,40 | 396/0,40 | 360/0,50 | 475/0,50 | 608/0,50 | 756/0,50 | ||||||
Insulation thickness | mm | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 | 3.0 | ||||||
Cable details | |||||||||||||||
Radial thickness of inner sheath | mm | 2.5 | 2.5 | 3.5 | 3.8 | 3.8 | 5.0 | 5.0 | 5.0 | ||||||
Size of armour | mm | 7/0,7 | 7/0,7 | 7/0,9 | 7/0,9 | 7/0,9 | 7/1,25 | 7/1,25 | 7/1,25 | ||||||
Radial thickness of outer sheath | mm | 4.0 | 5.0 | 5.3 | 5.8 | 6.7 | 6.8 | 7.2 | 7.6 | ||||||
Min. overall diameter | mm | 51.5 | 56.7 | 60.7 | 68.6 | 74.7 | 85.3 | 88.5 | 95.4 | ||||||
Max. overall diameter | mm | 55.8 | 60.1 | 64.1 | 72.3 | 78.4 | 89.2 | 93.7 | 99.3 | ||||||
Min. bending radius | mm | 503 | 541 | 577 | 651 | 706 | 803 | 844 | 894 | ||||||
Appx. cable weight | kg/km | 4.85 | 6.4 | 7.65 | 9.5 | 11.55 | 12.5 | 17.45 | 19 | ||||||
Copper weight | kg/km | 1.1 | 1.5 | 2 | 2.65 | 3.7 | 4.9 | 5.8 | 6.85 | ||||||
Electrical details | |||||||||||||||
“Continuous current rating at 25°C Ambient” | A | 85 | 110 | 135 | 170 | 205 | 250 | 295 | 345 | ||||||
Max. DC resistance at 20°C | |||||||||||||||
Conductors | Ω /km | 1.24 | 0.795 | 0.565 | 0.393 | 0.277 | 0.21 | 0.164 | 0.124 | ||||||
Armour | Ω /km | 1.40 | 0.96 | 0.90 | 0.79 | 0.73 | 0.47 | 0.44 | 0.38 |
Copyright © 2024 ÜNTEL KABLOLARI. All rights reserved.