M2XH-FFR (FI) Marine Certficated Cables

Certificates :

Application

Used on marine vehicles as fixed installation cables of various electromechanical and electronic equipments, where sustainable connection during fire is required.

*Minimum recommended installation temperature -15°C

For core identification, diameter tolerances and current ratings etc. see technical information section

CONDUCTOR : Electrolytic, stranded, annealed copper wire IEC 60228 Class 5 (Class 2 and / or tinned on request)
FIRE BARRIER : Mica tape
INSULATION : Cross linked polyethylene compound (XLPE)
INNER COVERING : Halogen-free compound
OUTER SHEATH : Halogen-free, flame retardant, UV resistant, thermoplastic polyolefin based compound (SHF 1)
COLOR : Orange or Green
FI : With extruded bedding compound

CONSTRUCTION : IEC 60092 / 353
TESTS AND MATERIAL : IEC 60092 / 350-360
FLAME RETARDANT : IEC 60332 / 1-2, IEC 60332 / 3-22 Cat A
FIRE RESISTANT : IEC 60331 / 21, IEC 60331 / 1-2
HALOGEN CONTENT : IEC 60754 / 1-2
SMOKE EMISSION : IEC 61034 / 1-2 (DIN EN 50268 / 1-2)
OZON RESISTANCE : IEC 60811 / 403
WORKING TEMPERATURE : -40°C / + 90°C
MIN. BENDING RADIUS (FIXED) : For cables D ≤ 25 mm 4xD, For cables D > 25 mm 6xD
RATED VOLTAGE : 0,6 / 1 kV
TEST VOLTAGE : 3,5 kV
UV AND SUNLIGHT RESISTANCE : EN 50289-4-17 A&B, ISO 4892-2&3

MGM 110 DOUBLE LA VER ARMOURED SIGNAL CABLE
Cross section2×1,54×1,57×1,510×1,512×1,514×1,519×1,537×1,561×1,591×1,5
Conductors
Number and cross sectionmm22×1,54×1,57×1,510×1,512×1,514×1,519×1,537×1,561×1,591×1,5
Strandingmm7/0,5
Conductor diameterNam. mm1.50
lnsu/ation thicknessmm0.5
Core diametermm2,36 (min) – 2,64 (max)
Cable details
Radia/ thickness of inner sheathmm1.01.01.01.01.01.01.01.21.21.4
Size of armourmm1/0,91/0,91/0,91/1,251/1,251/1,251/1,251/1,61/1,61/2,0
Radial thickness of outer sheathmm1.51.61.61.71.71.71.81.92.12.3
Min. overa/1 diametermm15.917.017.522.823.223.825.332.537.745.1
Max. overa/1 diametermm17.318.619.124.424.825.827.334.940.147.9
Min. bending radiusmm156168172220224233246315361432
Appx. cab/e weightkg/km5706808201,2801,3501,4501,6502,8503,0005,600
Copper weightkg/km30601051501802102805408801,315
MGM 110 DOUBLE LA VER ARMOURED TELEPHONE CABLE
Cross section1x2x1,52x2x1,54x2x1,57x2x1,510x2x1,512x2x1,519x2x1,527x2x1,530x2x1,537x2x1,548x2x1,561x2x1,5
Conductors
Number and cross sectionmm21x2x1,52x2x1,54x2x1,57x2x1,510x2x1,512x2x1,519x2x1,527x2x1,530x2x1,537x2x1,548x2x1,561x2x1,5
Strandingmm7/0,5
Conductor diameterNam. mm1.50
lnsu/ation thicknessmm0.5
Core diametermm2,36 (min) – 2,64 (max)
Cable details
Radia/ thickness of inner sheathmm1.01.01.01.01.21.21.21.41.41.41.41.6
Size of armourmm1/0,91/0,91/1,251/1,251/1,61/1,61/1,61/2,01/2,01/2,01/2,01/2,5
Radial thickness of outer sheathmm1.41.51.61.71.91.92.02.22.22.32.42.6
Min. overa/1 diametermm15.917.022.725.332.032.436.243.644.747.352.558.8
Max. overa/1 diametermm17.318.624.427.334.034.838.646.247.350.155.362.0
Min. bending radiusmm156168220246306314348416426451498558
Appx. cab/e weightkg/km5706801,2501,5802,3502,5503,2804,6804,9505,6206,5908,800
Copper weightkg/km30601202102903505507808701,0701,3901,760
We use cookies on our website to provide you a better experience. For detailed information please visit our Cookie Policy and Clarification Text.