We use cookies on our website to provide you a better experience. For detailed information please visit our Cookie Policy and Clarification Text.
Application
These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.
Available Features on Request
• 300 V version
• Yv type reinforced sheath
• Hydrocarbon resistant
• Anti termit / anti rodent
• Oil resistant
• LSF (Low Smoke) version
• UV resistant
• Multi core / Multi triple / Multi quad
CONDUCTOR :Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)
INSULATION :PE-Polyethylene compound to EN50290-2-23 Black / White twisted pairs with numbered cores
BINDER TAPE :Polyester foil on overall cable core formed by stranded pairs
COLLECTIVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
INNER SHEATH :PVC compound to EN50290-2-22
ARMOUR :Round galvanised steel wires EN 10257-1
OUTER SHEATH :Flame retardant PVC compound to EN50290-2-22 Blue for intrinsically safe cable Black for UV resistant and/or non-instrinsically safe cable Other colours on request
RATED VOLTAGE :500 V a.c.
AC TEST VOLTAGE :2000 V x 1 min. (core:core / core: screen)
WORKING TEMPERATURE : -30°C / + 70°C (during operation) – 5 °C / + 50°C (during installation)
MIN BENDING RADIUS (FIXED) :10 x D
CONSTRUCTION :EN 50288-7
MATERIAL TYPES & TESTS :EN 50290-2 series
ELECTRICAL & MECHANICAL TESTS :EN 50289 series
FLAME RETARDANT :IEC 60332 / 1-2, IEC 60332 / 3-24 Cat C
Conductor size (Class 2) | nom. | mm2 | 0.5 | 0.75 | 1 | 1.3 | 1.5 | 2.5 |
---|---|---|---|---|---|---|---|---|
Conductor resistance | max. | Ω/km | 36.7 | 25 | 18.5 | 14.2 | 12.3 | 7.6 |
Insulation resistance | min. | MΩxkm | 5000 | |||||
Mutual Capacitance | max. | nF/km | 150 | |||||
Inductance | max. | mH/km | 1 | |||||
L/R ratio | max. | µH/Ω | 25 | 25 | 25 | 40 | 40 | 60 |
(*) At 20 °C |
Cross Sections (mm2) | Nominal Overall Diameter (mm) | Approximate Weight (kg/km) |
---|---|---|
1x2x0,5 | 10.7 | 218 |
2x2x0,5 | 13.4 | 314 |
4x2x0,5 | 14.9 | 384 |
5x2x0,5 | 15.8 | 425 |
6x2x0,5 | 16.7 | 465 |
8x2x0,5 | 18.3 | 540 |
10x2x0,5 | 20.7 | 728 |
12x2x0,5 | 21.4 | 782 |
16x2x0,5 | 23.1 | 900 |
20x2x0,5 | 25.3 | 1041 |
24x2x0,5 | 27.3 | 1163 |
1x2x0,75 | 11.5 | 252 |
2x2x0,75 | 14.6 | 360 |
4x2x0,75 | 16.1 | 443 |
5x2x0,75 | 17.1 | 490 |
6x2x0,75 | 18.4 | 548 |
8x2x0,75 | 20.7 | 748 |
10x2x0,75 | 22.9 | 873 |
12x2x0,75 | 23.5 | 930 |
16x2x0,75 | 25.6 | 1084 |
20x2x0,75 | 27.9 | 1253 |
24x2x0,75 | 30.5 | 1428 |
1x2x1 | 11.7 | 264 |
2x2x1 | 14.9 | 377 |
4x2x1 | 16.5 | 470 |
5x2x1 | 17.7 | 530 |
6x2x1 | 18.9 | 590 |
8x2x1 | 21.5 | 820 |
10x2x1 | 23.5 | 833 |
12x2x1 | 24.1 | 998 |
16x2x1 | 26.4 | 1183 |
20x2x1 | 29 | 1384 |
24x2x1 | 32.2 | 1753 |
1x2x1,3 | 12.1 | 281 |
2x2x1,3 | 15.5 | 409 |
4x2x1,3 | 17.5 | 532 |
5x2x1,3 | 18.6 | 592 |
6x2x1,3 | 19.8 | 660 |
8x2x1,3 | 22.6 | 910 |
10x2x1,3 | 24.8 | 1050 |
12x2x1,3 | 25.7 | 1152 |
16x2x1,3 | 27.9 | 1354 |
20x2x1,3 | 30.7 | 1587 |
24x2x1,3 | 34.7 | 2060 |
1x2x1,5 | 12.3 | 291 |
2x2x1,5 | 15.9 | 426 |
4x2x1,5 | 17.9 | 556 |
5x2x1,5 | 19.1 | 626 |
6x2x1,5 | 21 | 811 |
8x2x1,5 | 23.2 | 955 |
10x2x1,5 | 25.7 | 1126 |
12x2x1,5 | 26.4 | 1213 |
16x2x1,5 | 28.9 | 1444 |
20x2x1,5 | 32.3 | 1868 |
24x2x1,5 | 35.7 | 2190 |
1x2x2,5 | 13.5 | 342 |
2x2x2,5 | 18 | 530 |
4x2x2,5 | 21 | 822 |
5x2x2,5 | 22.6 | 934 |
6x2x2,5 | 24.2 | 1049 |
8x2x2,5 | 26.8 | 1251 |
10x2x2,5 | 29.8 | 1470 |
12x2x2,5 | 30.7 | 1621 |
16x2x2,5 | 34.8 | 2187 |
20x2x2,5 | 38.3 | 2570 |
24x2x2,5 | 42 | 2960 |