Home » Instrumentation Cables » RE-2Y(St)YSWAY-fl PIMF

RE-2Y(St)YSWAY-fl PIMF

RE-2Y(St)YSWAY-fl PIMF Enstrümantasyon Kablosu

Certificates :

Application
These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.

Available Features on Request

• 300 V version

• Yv type reinforced sheath

• Hydrocarbon resistant

• Anti termit / anti rodent

• Oil resistant

• LSF (Low Smoke) version

• UV resistant

CONDUCTOR :Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)
INSULATION :PE-Polyethylene compound to EN50290-2-23 Black / White twisted pairs with numbered cores
BINDER TAPE :Polyester foil on each twisted pair
INDIVIDUAL SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
BINDER TAPE :Polyester foil on overall cable core formed by stranded pairs
COLLECTIVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
INNER SHEATH :PVC compound to EN50290-2-22
ARMOUR :Round galvanised steel wires to EN 10257-1
OUTER SHEATH :Flame retardant PVC compound to EN50290-2-22 Blue for intrinsically safe cable Black for UV resistant and/or non-instrinsically safe cable Other colours on request

RATED VOLTAGE :500 V a.c.
AC TEST VOLTAGE :2000 V x 1 min. (core:core / core: screen)
WORKING TEMPERATURE : -30°C / + 70°C (during operation) – 5 °C / + 50°C (during installation)
MIN BENDING RADIUS (FIXED) :10 x D
CONSTRUCTION :EN 50288-7
MATERIAL TYPES & TESTS :EN 50290-2 series
ELECTRICAL & MECHANICAL TESTS :EN 50289 series
FLAME RETARDANT :IEC 60332 / 1-2, IEC 60332 / 3-24 Cat C

Conductor size (Class 2)nom.mm20.50.7511.31.52.5
Conductor resistancemax.Ω/km36.72518.514.212.37.6
Insulation resistancemin.MΩxkm5000
Mutual Capacitancemax.nF/km150
Inductancemax.mH/km1
L/R ratiomax.µH/Ω252525404060
(*) At 20 °C
Cross Sections (mm2)Nominal Overall Diameter (mm)Approximate Weight (kg/km)
2x2x0,514.7361
4x2x0,516.3447
5x2x0,517.5508
6x2x0,518.7560
8x2x0,521.3775
10x2x0,523.3890
12x2x0,523.9950
16x2x0,526.21118
20x2x0,528.61281
24x2x0,5321660
2x2x0,7515.8408
4x2x0,7517.8521
5x2x0,7519578
6x2x0,7521761
8x2x0,7523.2890
10x2x0,7525.71043
12x2x0,7526.41115
16x2x0,75291325
20x2x0,7532.61723
24x2x0,7535.91998
2x2x116.2425
4x2x118.3550
5x2x119.5616
6x2x121.8815
8x2x123.8951
10x2x126.51108
12x2x127.21197
16x2x129.81415
20x2x133.61856
24x2x137.22170
2x2x1,316.9460
4x2x1,319.1604
5x2x1,321.4805
6x2x1,322.9902
8x2x1,325.31068
10x2x1,3281240
12x2x1,328.91347
16x2x1,332.31785
20x2x1,335.92123
24x2x1,339.42441
2x2x1,517.5490
4x2x1,519.6630
5x2x1,521.9850
6x2x1,523.4940
8x2x1,525.91114
10x2x1,528.91308
12x2x1,529.71421
16x2x1,533.31885
20x2x1,537.12260
24x2x1,540.72595
2x2x2,519.7594
4x2x2,523.2926
5x2x2,525.11062
6x2x2,526.91188
8x2x2,529.91432
10x2x2,534.61935
12x2x2,535.62105
16x2x2,539.12502
20x2x2,544.23270
24x2x2,548.93804