Search
Close this search box.

Search

Search
Close this search box.
Home » Instrumentation Cables » RE-2X(St)HSWAH-TIMF..CI

RE-2X(St)HSWAH-TIMF..CI

RE-2XStHSWAH-TIMF..CI_ enstrümantasyon kabloları

Certificates :

Application
These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply. Recommended for use where circuit integrity is required in case of fire.

Available Features on Request

• 300 V version

• Hv type reinforced sheath

• Hydrocarbon resistant

• Anti termit / anti rodent

• Oil resistant

• UV resistant

CONDUCTOR :Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)
INSULATION :Mica tape + XLPE compound to EN50290-2-29 Black / White / Red twisted triads with numbered cores
BINDER TAPE :Polyester foil on each twisted triad
INDIVIDUAL SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
BINDER TAPE :Polyester foil on overall cable core formed by stranded pairs
COLLECTIVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
INNER SHEATH :LSZH compound to EN50290-2-27
ARMOUR :Round galvanised steel wires to EN 10257-1
OUTER SHEATH :Halogen free flame retardant LSZH compound to EN50290-2-27 Orange or Red for circuit integrity Blue for intrinsically safe cable Black for UV resistant and/or non-instrinsically safe cable

RATED VOLTAGE :500 V a.c.
AC TEST VOLTAGE :2000 V x 1 min. (core:core / core: screen)
WORKING TEMPERATURE :-40°C / + 90°C (during operation) – 5 °C / + 50°C (during installation)
MIN BENDING RADİUS (FIXED) :10 x D
CONSTRUCTION :EN 50288-7
MATERIAL TYPES & TESTS :EN 50290-2 series
ELECTRICAL & MECHANICAL TESTS :EN 50289 series
FLAME RETARDANT :IEC 60332 / 1-2, IEC 60332 / 3-24 Cat C
FIRE RESISTANCE :IEC 60331 / 21, IEC 60331 / 1-2
HALOGEN CONTENT :IEC 60754 / 1-2
SMOKE EMISSION :IEC 61034 / 1-2

Conductorsize(Class2),nom.,mm2,0.5,0.75,1,1.3,1.5,2.5
Conductorresistance,max.,Ω/km,36.7,25,18.5,14.2,12.3,7.6
Insulationresistance,min.,MΩxkm,5000,,,,,
MutualCapacitance,max.,nF/km,150,,,,,
Inductance,max.,mH/km,1,,,,,
L/Rratio,max.,µH/Ω,25,25,25,40,40,60
(*)At20°C
Cross Sections (mm2)Nominal Overall Diameter (mm)Approximate Weight (kg/km)
2x3x0,517.7475
4x3x0,519.9604
5x3x0,522.2810
6x3x0,523.8903
8x3x0,526.31061
10x3x0,529.31240
12x3x0,530.21336
16x3x0,533.81774
20x3x0,537.72117
24x3x0,541.42421
2x3x0,7518.6518
4x3x0,7521.9805
5x3x0,7523.5897
6x3x0,7525.41012
8x3x0,7527.91187
10x3x0,7531.21396
12x3x0,75331712
16x3x0,7536.72067
20x3x0,7540.42403
24x3x0,7545.23062
2x3x119540
4x3x122.4848
5x3x124947
6x3x125.91068
8x3x128.61260
10x3x132.91695
12x3x133.81820
16x3x137.52218
20x3x141.42584
24x3x146.73330
2x3x1,319.8588
4x3x1,323.3921
5x3x1,325.21053
6x3x1,327.11177
8x3x1,330.11404
10x3x1,334.81900
12x3x1,335.82062
16x3x1,339.32460
20x3x1,344.43200
24x3x1,349.23720
2x3x1,520.8717
4x3x1,523.7958
5x3x1,525.71097
6x3x1,527.61226
8x3x1,530.71476
10x3x1,535.51980
12x3x1,536.72172
16x3x1,540.42598
20x3x1,545.43350
24x3x1,550.33920
2x3x2,523.9900
4x3x2,527.31215
5x3x2,529.71404
6x3x2,5331795
8x3x2,537.12200
10x3x2,541.62594
12x3x2,543.63132
16x3x2,548.63850
20x3x2,553.74523
24x3x2,560.85805
We use cookies on our website to provide you a better experience. For detailed information please visit our Cookie Policy and Clarification Text.