PENDANT

Certificates :

APPLICATIONS

These pendant cables are used as control or feeder cables in lifts and hoists. The two steel load bearing elements can be detached without damaging the outer sheath and fixed independently from the cable gland The cable offers high flexibility at lower temperatures due to the quality of material used in the construction. The two special torsion-free steel supporting elements found parallel on both sides of the outer jacket are. These cables are not suitable for drum reeling installations.

CONDUCTOR: Electrolytic annealed, Class 5 or Class 6 stranded plain copper wires (tinned conductor on request)
INSULATION: XLPE compound (Cross-linked polyethylene), 2XI1 type (VDE 0276- 604, IEC 60502-1) Black cores number coded with a green yellow core
SEPERATOR: Textile tape
SUSPENSION SUPPORT: Galvanized steel wire ropes at both sides
SHEATH: Special PVC compound
COLOR: Black or Yellow

RATED VOLTAGE: 300/500 V (U0/U)
AC TEST VOLTAGE: 2 kV
OPERATING TEMPETATURE
IN FLEXING USE :-25°C to +90°C
IN FIXED USE: -40°C to +90°C
CONDUCTOR SHORT-CIRCUIT TEMP.: 250°C (Max. 5 sec)
MIN. INSTALLATION TEMP.: -5°C
MIN. BENDING RADIUS
FLEXIBLE USE: 10 x Outer DIameter
FIXED INSTALLATION: 4 x Outer DIameter
MAX. SUSPENDED HEIGHT: 80m
CURRENT CARRYING CAPACITIES: Based on. VDE 0298-4 Tab.11

Cross Section (mm²)Nominal Overall Diameter (mm)Approximate Weight
(kg / km)
Min.Bending Radius
(free movement) (mm)
Max. Resistance of Conductors
at 20°C (ohm / km)
5×1,5 10,50 x 20,00 255 105 1,91 
6×1,5 11,20 x 21,00 275 112 1,21 
8×1,5 13,50 x 22,50 335 135 0,780 
10×1,5 14,50 x 23,00 380 145 0,554 
12×1,5 15,00 x 23,50 415 150 0,386 
14×1,5 15,50 x 24,50 455 155 0,272 
16×1,5 16,00 x 25,00 495 160 0,206 
20×1,5 17,50 x 27,50 610 175 0,161 
24×1,5 19,50 x 29,50 645 195 0,129