Search
Close this search box.

بحث

Search
Close this search box.

RE-Y(St)Y-fl PIMF

RE-Y(St)Y-fl PIMF Enstrümantasyon Kablosu

Certificates :

Application
These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.

Available Features on Request

• 300 V version

• Yw 105ºC version

• Hydrocarbon resistant

• Yv type reinforced sheath

• Oil resistant

• Anti termit / anti rodent

• UV resistant

• LSF (Low Smoke) version

CONDUCTOR :Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)
INSULATION :PVC compound to EN50290-2-21 Black / White twisted pairs with numbered cores
BINDER TAPE :Polyester foil on each twisted pair
INDIVIDUAL SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
BINDER TAPE :Polyester foil on overall cable core formed by stranded pairs
COLLECTIVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
OUTER SHEATH :Flame retardant PVC compound to EN50290-2-22 Blue for intrinsically safe cable Black for UV resistant and/or non-instrinsically safe cable Other colours on request

CONDUCTOR :Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)
INSULATION :PVC compound to EN50290-2-21 Black / White twisted pairs with numbered cores
BINDER TAPE :Polyester foil on each twisted pair
INDIVIDUAL SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
BINDER TAPE :Polyester foil on overall cable core formed by stranded pairs
COLLECTIVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil
OUTER SHEATH :Flame retardant PVC compound to EN50290-2-22 Blue for intrinsically safe cable Black for UV resistant and/or non-instrinsically safe cable Other colours on request

Conductor size (Class 2)nom.mm20.50.7511.31.52.5
Conductor resistancemax.Ω/km36.72518.514.212.37.6
Insulation resistancemin.MΩxkm100
Mutual Capacitancemax.nF/km250
Inductancemax.mH/km1
L/R ratiomax.µH/Ω252525404060
(*) At 20 °C
Cross Sections (mm2)Nominal Overall Diameter (mm)Approximate Weight (kg/km)
2x2x0,510.1102
4x2x0,511.7156
5x2x0,513190
6x2x0,514.1220
8x2x0,516284
10x2x0,518.2351
12x2x0,518.8400
16x2x0,521.1516
20x2x0,523.7636
24x2x0,526.4759
2x2x0,7511.2122
4x2x0,7513.2197
5x2x0,7514.4234
6x2x0,7516279
8x2x0,7518.1360
10x2x0,7520.6445
12x2x0,7521.3509
16x2x0,7524567
20x2x0,7526.8809
24x2x0,7530966
2x2x111.6133
4x2x113.7218
5x2x115260
6x2x116.5310
8x2x118.7400
10x2x121.4532
12x2x122.1569
16x2x124.7735
20x2x127.8907
24x2x1311084
2x2x1,312.5158
4x2x1,314.5254
5x2x1,316.1311
6x2x1,317.6363
8x2x1,320470
10x2x1,323584
12x2x1,323.8683
16x2x1,326.7884
20x2x1,3301090
24x2x1,333.41302
2x2x1,513168
4x2x1,515.2279
5x2x1,516.6334
6x2x1,518.3398
8x2x1,520.8515
10x2x1,523.8638
12x2x1,524.6735
16x2x1,527.5951
20x2x1,530.91175
24x2x1,534.71420
2x2x2,515.3234
4x2x2,518.1395
5x2x2,519.8475
6x2x2,521.8566
8x2x2,524.8734
10x2x2,528.4911
12x2x2,529.61069
16x2x2,533.11385
20x2x2,537.41728
24x2x2,541.72062